期刊文献+

人工显微镜检查在血液 尿液 粪便检验中的运用 被引量:1

The use of artificial microscopy in blood,urine,and excremment tests
下载PDF
导出
摘要 传统的血液、尿液、粪便手工检验虽然被现代化的全自动检测仪所代替,但仍不能全部满足检出有临床病理意义的异常细胞的需要。各类分析仪尚不具备人脑识别红细胞、白细胞、血小板等各种细胞形态及管型、结晶、寄生虫、细菌等形态学的全面判断综合能力。因此,仪器检测尚不能完全代替人工显微镜对各类细胞(特别是骨髓细胞和异常细胞)等的识别和分类检查。为了保证血液、尿液、粪便检测结果的真实性和提供有价值的诊断依据,对异常检测结果须进一步用显微镜复检验证。 Traditional blood,urine,excremment manual inspection is replaced by the modern automatic detection apparatus,but it still can not meet the needs of abnormal cells in clinical pathology. All kinds of analyzers do not have the human brain to identify the red blood cells,white blood cells,platelets and other cells morphology and tube type, crystallization,parasites,bacteria and other morphological comprehensive ability to judge. Therefore,the detection of the instrument can not completely replace the manual microscope for various types of cells(especially bone marrow cells and abnormal cells),such as recognition and classification. So in order to ensure the authenticity of the blood,urine and excremment test results and provide to the clinical value of diagnosis,in the face of the abnormal test results to further verified by microscope recheck.
作者 吕海燕
出处 《基层医学论坛》 2016年第20期2812-2813,共2页 The Medical Forum
关键词 血液 尿液 粪便 人工显微镜 复检 Blood Urine Faeces Artificial microscope Recheck
  • 相关文献

参考文献5

二级参考文献25

  • 1贺淑霞,张洁.UF-100尿沉渣分析仪检查尿管型的评价[J].国际检验医学杂志,2007,28(3):265-265. 被引量:5
  • 2丛玉隆,乐家新.再论血细胞分析技术进展与临床应用[J].中华检验医学杂志,2007,30(4):365-370. 被引量:62
  • 3赵永昌.UF-50尿沉渣分析仪与尿干化学不能取代显微镜镜检.临床医学检验与技术,2008,11(2):116-117. 被引量:2
  • 4张之南,沈悌.血液病诊断及疗效标准[M].北京:科学出版社,2008.103-122,131-134,172-176. 被引量:51
  • 5Kadkhoda K, Manickam K, De Gagne P, et al. UF-1000i flow cy- tometry is an effective screening method for urine specimens[J]. Diagno Microbiol Infect Dis,2011,69(2) : 130-136. 被引量:1
  • 6Manoni F, Tinello A, Fornasiero L, et al. Urine particle evalua- tion:a eomparison between the UF-1000i and quar/titative micros- copy[J]. Clin Dhem Laborat Med, 2010,48 (8) : 1107-1111. 被引量:1
  • 7Jiang T, Chen PS, Ouyang J, et al. Urine particles analysis: per- formance evaluation of Sysmex UF-1000i and comparison among urine flow cytometer, dipstick, and visual microscopic examination [J]. Scand J Clin Lab Invest,2011,71(1) :30-37. 被引量:1
  • 8Fabbro C, Darolles J, Rault JP. Preservation of urine samples for UF-1000i[-bio Mfirieux@] analysis[J]. Ann Biol Clin(Paris), 2011,69(5) : 588-592. 被引量:1
  • 9Bain BJ. Diagnosis from the blood smearfJ]. N Engl J Med, 2005,353 (5) : 498-507. 被引量:1
  • 10Barnes PW, McFadden SL, Machin SJ, et al. The in- ternational consensus group for hematology'review: suggested criteria for action following automated CBC and WBC differential analysis [-J 3. Lab Hematol, 2005,11(2) :83-90. 被引量:1

共引文献40

引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部