期刊文献+

基于激光诱导击穿光谱的化验室水泥质量检测设备研制 被引量:6

Development of a Laboratory Cement Quality Analysis Apparatus Based on Laser-Induced Breakdown Spectroscopy
下载PDF
导出
摘要 研制了一套基于激光诱导击穿光谱(LIBS)的化验室水泥质量检测设备,可对水泥生熟料成分及率值进行快速检测。对该设备的总体结构、光学系统、样本制备、光谱处理方法等几方面进行了介绍。通过内标法建立定标模型,将LIBS测量结果与X射线荧光光谱分析(XRF)结果进行了对比分析,该套LIBS设备对水泥生熟料中CaO,SiO_2,Al_2O3和Fe_2O3测量的平均绝对误差分别为0.46%,0.25%,0.13%和0.05%,对水泥熟料率值KH,SM,IM测量的平均绝对误差分别为0.02,0.05和0.04;通过计算激发产生的等离子体温度和电子密度,验证了激光诱导水泥等离子体处于局部热平衡(LTE)态。 A laboratory cement quality analysis apparatus based on laser-induced breakdown spectroscopy (LIBS) has been devel-oped for rapid analysis of cement composition and ratio values .In this paper ,the overall structure ,the optical system ,the sam-ple preparation process ,as well as the spectral data analysis methods are introduced .The calibration model is established with internal standard method . A comparison as to the measurement results between LIBS and X-ray fluorescence spectrometry (XRF) has been made and being analyzed .It shows that by using the LIBS apparatus ,the mean absolute error of CaO ,SiO2 , Al2 O3 ,and Fe2 O3 in cement raw materials is 0.46% ,0.25% ,0.13% ,and 0.05% ,respectively ,while the mean absolute error of the ratio value such as KH ,SM ,and IM in cement clinker is 0.02 ,0.05 ,and 0.04 ,respectively .The generated cement plas-mas are verified to be in the local thermal equilibrium (LTE) condition by calculating both the plasma temperature and the elec-tron density .
出处 《光谱学与光谱分析》 SCIE EI CAS CSCD 北大核心 2016年第7期2249-2254,共6页 Spectroscopy and Spectral Analysis
基金 国家自然科学基金项目(61475093 61205216 61378047) 国家科技支撑计划项目(2013BAC14B01) 山西省青年科学基金项目(2013021004-1)资助
关键词 激光诱导击穿光谱 水泥生熟料 平均绝对误差 率值 局部热平衡态 Laser-induced breakdown spectroscopy Cement raw materials Mean absolute error Ratio values Local thermal e-quilibrium
  • 相关文献

参考文献1

二级参考文献24

  • 1R. Noll, Laser-Induced Breakdown Spectroscopy: Fundamentals and Applications, Berlin Heidelberg: Springer, 2012. 被引量:1
  • 2N. H. Cheung, Resonance-Enhanced LIBS, in: Laser Induced Breakdown Spectroscopy: Fundamentals and Applications, edited by A. Miziolek, V. Palleschi, and I. Schechter, London: Cambridge University Press, 2006. 被引量:1
  • 3D. J. Butcher, Appl. Spectrosc. Rev., 2005, 40(2): 147. 被引量:1
  • 4S. K. Ho and N. H. Cheung, Anal. Chern., 2005, 77(1): 193. 被引量:1
  • 5S. K. Ho and N. H. Cheung, Appl, Phys. Lett., 2005, 87(26): 264104. 被引量:1
  • 6S. K. Ho and N. H. Cheung, J. Anal. At. Spectrom., 2007, 22(3): 292. 被引量:1
  • 7S. K. Lau and N. H. Cheung, Appl. Spectrosc., 2009, 63(7): 835. 被引量:1
  • 8P. C. Chu, W. L. Yip, Y. Cai, and N. H. Cheung, J. Anal. At. Spectrorn., 2011, 26(6): 1210. 被引量:1
  • 9N. H. Cheung, Appl. Spectrosc. Rev., 2007, 42(3): 235. 被引量:1
  • 10Y. Cai and N. H. Cheung, Microchem. J., 2011, 97(2): 109. 被引量:1

共引文献3

同被引文献21

引证文献6

二级引证文献26

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部