期刊文献+

双色硅橡胶法测定DeBel生物激光烤瓷冠边缘适合性的实验研究

Determining the marginal adaptation of De Bel laser ceramic crowns with bicolor silicone rubber
下载PDF
导出
摘要 目的以传统钴铬烤瓷冠为对照,通过测定完全边缘缝隙,研究De Bel生物激光烤瓷冠的边缘适合性。方法制作上颌第一磨牙全冠牙体制备标准金属代型1个,复制并灌注20个石膏模型后,制作De Bel生物激光烤瓷冠和传统钴铬烤瓷冠各10个。加工完成后,将修复体在金属代型上就位,采用双色硅橡胶法复制修复体内表面与代型外表面之间的间隙大小,并将获得的硅橡胶块沿冠的颊舌向及近远中向的中线切开,分为4份。体视显微镜下,采集每个剖面上修复体边缘位置的数码图像,并测量两组钴铬烤瓷冠的完全边缘缝隙。最后计算各组10个样本的平均值,采用SPSS 19.0软件包对数据进行统计学处理。结果 De Bel生物激光烤瓷冠与传统钴铬烤瓷冠的完全边缘缝隙分别为77.13士8.30μm和95.96士9.00μm,差异具有统计学意义(P<0.05)。结论 De Bel生物激光烤瓷与传统钴铬烤瓷冠的边缘适合性均在临床可接受范围,但前者的边缘适合性更好。 Objective To determine the marginal adaption of De Bel laser ceramic crowns as compared with that of the traditional Cobalt-chromium metal-ceramic crowns. Method Firstly,twenty working dies were created from a single master die and used to fabricate twenty copings. Then,De Bel laser ceramic crowns( n = 10) and traditional Cobalt-chromium metal-ceramic crowns( n = 10) were made. The restorations were seated on the master die. Bicolor silicone rubber replica method was used to record the gap between the crown and the die. High-resolution digital photographs were made and absolute marginal discrepancy was then measured with a calibrated digital software program. Findings Absolute marginal discrepancy was 77. 13 士 8. 30 μm in De Bel laser ceramic crowns while it was 95. 96 士 9. 00μm in traditional Cobaltchromium metal-ceramic crowns. The difference between them was statistically significant( P〈0. 05). Conclusion Both De Bel laser ceramic crowns and traditional Cobalt-chromium metal-ceramic crowns produce acceptable marginal adaptation in clinical practice. However,the former produces better marginal adaptation than the latter.
出处 《健康研究》 CAS 2016年第3期267-269,共3页 Health Research
基金 宁波市医学科技计划项目(2014A28)
关键词 选择性激光熔覆技术 钴铬合金 边缘适合性 selective laser melting(SLM) Cobalt-chromium alloy marginal adaptation
  • 相关文献

参考文献8

  • 1马丁,湛渝.浅析金属烤瓷冠边缘适合性的影响因素[J].口腔医学研究,2007,23(4):460-461. 被引量:4
  • 2Tsitrou EA,Northeast SE,van Noort R.Evaluation of the marginal fit of three margin designs of resin composite crowns using CAD/CAM[J].J Dent,2007,35(1):68-73. 被引量:1
  • 3Reich S,Uhlen S,Gozdowski S,et al.Measurement of cement thickness under lithium disilicate crowns using an impression material technique[J].Clin Oral Investig,2011,15(4):521-526. 被引量:1
  • 4Holmes JR,Bayne SC,Holland GA,et al.Considerations in measurement of marginal fit[J].J Prosthet Dent,1989,62(4):405-408. 被引量:1
  • 5Cho LR,Song HY,Koak JY,et al.Marginal accuracy and fracture strength of ceromer/fiber-reinforced composite crown,Effect of variation in preparation design[J].J Prosthet Dent,2002,88(4):388-395. 被引量:1
  • 6Mclean JW,Von Fraunhofer JA.The estimation of cement film thickness by an in vivo technique[J].Br Dent J,1971,131(3):107-111. 被引量:1
  • 7Van Noort R.The future of dental devices is digital[J].Dent Mater,2012,28(1):3-12. 被引量:1
  • 8Mumtaz KA,Erasenthiran P,Hopkinson N.High density selective laser melting of Waspaloy[J].Journal of Materials Processing Technology,2008,195(1-3):77-87. 被引量:1

二级参考文献15

  • 1马轩样.口腔修复学[M].第5版.北京:人民卫生出版社,2003:109 被引量:2
  • 2Hansal K,Walter MH,Kastner C et al.Effect of posterior crown margin placement on gingival health[J].J Prosthet Dent,2002,8(7):167 -172 被引量:1
  • 3Cho LR,Choi JM,Yi Yj,et al.Effect of finish line variants on marginal accuracy and fracture strenth of ceramic optimized polymer/fiber-reinforced composite crowns[J].J Prosthet Dent,2004,9(1):554 -560 被引量:1
  • 4Petteno D,Schierano G,Bassi F,et al.Comparison of marginal fit of 3 different metal-ceramicsystems:an invitro study[J].Int Prosthodont,2000,13(5):405-408 被引量:1
  • 5Boeckler AF,Stacller A,Setz JM.The significance of marginal gap and overextension measurement in the evaluation of the fit of complete crowns[J].The Journal of contemporary Dental practice,2005,6(4):1-12 被引量:1
  • 6Walfart S,Wegner SM,AL Halabi A,et al.Clinical evaluation of marginal fit of a new experimental all-ceramic system before and after cementationInt[J].J Prosthodont,2003,16(6):587-592 被引量:1
  • 7Kihn P W,BarnesDM.The clinical longevity of porcelain veneers:A 48 -month clinical evaluation[J].J Am Dent Assoc,1998,129:747-752 被引量:1
  • 8Proos KA,Swain MV,Ironside J.Influence of margin design and taper abutment angle on a restored crown of a first premolar using finite element analysis[J].Int J Prosthodont,2003,1 (6):442-449 被引量:1
  • 9Shiratsuchi H,Komine F,Kakehashi Y.Influence of finish line design on marginal adaptation of electroformed metal-ceramic crowms[J].J Prosthet Dent,2006,9(5):237 -242 被引量:1
  • 10Tuntiprawon.Effect of tooth surface roughness on marginal seating and retention of complete crowns[J].J Prosthet Dent,1998,75(1):4-8 被引量:1

共引文献3