以核安全相关法规导则为基础,结合核安全导则中对安全专设系统的调试要求,分别对AP1000非能动堆芯冷却系统和非能动安全壳冷却系统主要试验项目进行适应性分析。结果表明:AP1000非能动安全专项系统的调试符合核安全法规导则的要求,但需进一步优化试验项目的设置;建议今后在核安全法规导则升版时,可考虑增加对非能动安全专设系统的调试要求以及对现场难以实施而通过试验台架或仿真模拟的试验项目的要求。
Firstly the Nuclear safety laws and guidelines was introduced briefly, and then the requirement of safety systems in nuclear safety laws and guidelines was decrebied, and the adaptability of passive core cooling system and passive containment cooling system commissioning to laws and guidelines was analysied. The results show that the commissioning of AP1000 passive safety systems are adptive to the laws and guidelines of nuclear safety, but the sequence of the related tests should be optimized. When the laws and guidelines are updated in the future, these commissioning of passive safety systems and these tests cannot be performed on site due to test conditions should be taken into account.
出处
《核动力工程》
EI
CAS
CSCD
北大核心
2016年第3期110-115,共6页
Nuclear Power Engineering
基金
上海市科技启明星计划(14QB1400300)
关键词
AP1000核电厂
非能动安全专设系统
调试
核安全法规导则
适应性