期刊文献+

AP1000非能动安全系统调试与核安全法规适应性分析 被引量:1

Analysis of Adaptability of AP1000 Passive Safety Systems Commissioning to Nuclear Safety Laws and Guidelines
原文传递
导出
摘要 以核安全相关法规导则为基础,结合核安全导则中对安全专设系统的调试要求,分别对AP1000非能动堆芯冷却系统和非能动安全壳冷却系统主要试验项目进行适应性分析。结果表明:AP1000非能动安全专项系统的调试符合核安全法规导则的要求,但需进一步优化试验项目的设置;建议今后在核安全法规导则升版时,可考虑增加对非能动安全专设系统的调试要求以及对现场难以实施而通过试验台架或仿真模拟的试验项目的要求。 Firstly the Nuclear safety laws and guidelines was introduced briefly, and then the requirement of safety systems in nuclear safety laws and guidelines was decrebied, and the adaptability of passive core cooling system and passive containment cooling system commissioning to laws and guidelines was analysied. The results show that the commissioning of AP1000 passive safety systems are adptive to the laws and guidelines of nuclear safety, but the sequence of the related tests should be optimized. When the laws and guidelines are updated in the future, these commissioning of passive safety systems and these tests cannot be performed on site due to test conditions should be taken into account.
出处 《核动力工程》 EI CAS CSCD 北大核心 2016年第3期110-115,共6页 Nuclear Power Engineering
基金 上海市科技启明星计划(14QB1400300)
关键词 AP1000核电厂 非能动安全专设系统 调试 核安全法规导则 适应性 AP1000 Nuclear power plant, Passive safety system, Commissioning, Nuclear safety law and guideline, Adaptability analysis
  • 相关文献

参考文献12

二级参考文献68

  • 1郭玉君,张金玲,秋穗正,苏光辉,贾斗南,喻真烷.反应堆系统冷却剂泵流量特性计算模型[J].核科学与工程,1995,15(3):220-225. 被引量:20
  • 2Thomas,Hayes,Jeneifer,Kisakl,ü,陈世君(译),张延祥(校).AP1000电站描述[J].国外核动力,2005,26(4):1-6. 被引量:3
  • 3肖泽军,卓文彬,陈炳德,贾斗南.中国先进压水堆非能动余热排出系统瞬态特性研究[J].核动力工程,2005,26(6):548-553. 被引量:6
  • 4郭志锋.AP1000的非能动安全系统[J].国外核新闻,2005(9):14-20. 被引量:4
  • 5IAEA. Passive safety systems and natural circula- tion in water cooled nuclear power plants, IAEA TECD(-1624[R]. Vienna.. IAEA, 2009. 被引量:1
  • 6CHUNY J, YANG S H, KIM H C. Thermal hydraulic calculation in a passive heat removal of the SMART-P plant for forced and natural con- vection conditions[J]. Nuclear Engineering and Design, 2004, 232(3).. 277 288. 被引量:1
  • 7OHASHI K, HATAKAWA H, YMADA M. Preliminary study on the application of the heat pipe to the passive decay heat removal system ofthe modular HTR[J]. Progress in Nuclear Ener- gy, 1998, 32(3-4) 587-594. 被引量:1
  • 8ZANG X N, GUO W J, HUANG B, et al. Transient analysis of the passive residual heat system [J]. Nuclear Engineering and Design, 2001, 206(1).. 105-111. 被引量:1
  • 9苏光辉,郭玉君,秋穗正,等.核反应堆热工水力计算方法[M].西安:西安交通大学出版社,1995. 被引量:1
  • 10WANG D Q, WANG B S, JIANG J, et al. Transient analysis of a passive residual heat re- moval system following a station blackout acci- dent[C]///Proceedings of the 20th International Conference on Nuclear Engineering. California, USA: [s. n. ], 2012. 被引量:1

共引文献46

同被引文献1

引证文献1

二级引证文献2