摘要
对干式变压器的直流电阻不平衡及其影响进行研究。通过实例分析了线材、引线结构及外部负载对变压器直流电阻不平衡的影响,总结了引起电阻不平衡的原因及其影响。
The unbalanced DC resistance in dry-type transformer and it's influence are researched in this paper. The effects of the winding wire, lead structure and external load on the unbalanced DC resistance in transformer are analysed by example. The reason and the influence of the unbalanced DC resistance are summarized.
出处
《变压器》
北大核心
2014年第5期45-49,共5页
Transformer
关键词
干式变压器
直流电阻
不平衡
Dry-type transformer
DC resistance
Unbalance