摘要
本文针对某热电厂660 MW除氧器排气带水问题,进行了现场检查后,对排气带水的原因进行了分析,并对该除氧器排气系统的改造方案做了简要介绍,最后对除氧器排气管道布置提出了一点建议。
In this paper, against the issue of a 660MW power plant deaerator exhaust with water, the reasons are analyzed after checking in site, and the brief introduction of the reform program for the deaerator exhaust system is made. Finally, some suggestion is given for deaerator exhaust piping layout.
出处
《锅炉制造》
2016年第3期48-49,52,共3页
Boiler Manufacturing
关键词
除氧器
排气带水
管道布置
deaerator
exhaust with water
piping layout