摘要
以木垛火为火源开展全尺寸实体火灾试验,验证新型保护玻璃用喷头的可靠性及应用效果。玻璃试件为钢化玻璃和防火玻璃,厚度均为12 mm。在玻璃的受火面、背火面不同高度处设置热电偶,测量温度变化。研究结果表明,该喷头布水均匀,保证了玻璃防火分隔良好的完整性和隔热性。
The wood crib fire was used to carry out the full scale practical fire experiment to evaluate the safe reliability and ap plication effect of a novel sprinkler for protecting glasses. The fire glass and toughened glass which thickness was 12 mm were used in the experiment. The thermal couples were set at differ- ent height on the fire side and unexposed side of glass to test the change of temperature. The resuhs showed that, the nozzle can ensure the uniformity of water distribution on the surfaee of glasses, and the integrity and insulation performance of glass.
出处
《消防科学与技术》
CAS
北大核心
2016年第4期537-539,共3页
Fire Science and Technology
基金
公安部四川消防研究所科研项目(20148811Z)
关键词
玻璃用喷头
玻璃分隔
布水效果
防火玻璃
防
火分隔
novel sprinkler
glass fire divider
water distribution: fire glass
fire separation