摘要
本文所举的案例是限速器的速度监控有效,但与安全钳联动失效的情况。通过这个案例分析,反映出对老旧电梯检验以及限速器维保时应该注意的一些问题,并对限速器校验方法提出了改进的建议。
A case that the speed limiter-safety clamp linkage cannot act while the speed monitoring unit of speed limiter is effective, is decribed in this paper. This case reflects some problems that should paid attention in the inspection and maintenance of the old elevator. We put forward some suggestion for speed limiter calibration, to ensure the effective working of speed limiter.
出处
《中国特种设备安全》
2016年第2期25-26,31,共3页
China Special Equipment Safety
关键词
限速器
电梯
检验检测
维护保养
安全钳
限速器校验
Speed limiter
Elevator
Inspection
Maintenance
Safety gear
Speed limiter calibration