期刊文献+

基于滚球法的35kV模块化变电站直击雷防护设计 被引量:2

Direct lightning strike protection design based on the rolling sphere method for 35 kV modular substations
下载PDF
导出
摘要 以滚球法为基础,阐述了单支避雷针、双针等高、三针不等高保护范围计算的数学模型;针对模块化变电布置灵活性,提出防雷设计中的关键点,简化了变电站防直击雷设计过程;最后将滚球法应用到35 kV模块化变电站防直击雷设计中,弥补了模块化变电站布置的自由性可能带来的防雷安全漏洞。 This paper described the protection zone calculation mathematical models of single lightning rod,double needle contour,three stitches ranging from high based on the rolling sphere method,aimed at dealing with the flexible disposition of modular substations,this paper presented the key point in lightning protection design,simplified the design procedure. Finally the paper applied the method to lightning-protection design for 35 kV modular substation,made up for the security vulnerabilities from the freedom of modular substations' arrangement.
作者 黄峰远
机构地区 遵义供电局
出处 《贵州电力技术》 2016年第3期51-54,共4页 Guizhou Electric Power Technology
关键词 滚球法 模块化变电站 关键点 防雷设计 rolling sphere method modular substation key point lightning protection design
  • 相关文献

参考文献12

二级参考文献51

共引文献92

同被引文献16

引证文献2

二级引证文献2