期刊文献+

Design and implementation of GM- APD array readout circuit for infrared imaging

GM-APD阵列型红外传感读出电路设计与实现(英文)
下载PDF
导出
摘要 Based on an avalanche photodiode( APD) detecting array working in Geiger mode( GM-APD), a high-performance infrared sensor readout integrated circuit( ROIC) used for infrared 3D( three-dimensional) imaging is proposed. The system mainly consists of three functional modules, including active quenching circuit( AQC), time-to-digital converter( TDC) circuit and other timing controller circuit. Each AQC and TDC circuit together constitutes the pixel circuit. Under the cooperation with other modules, the current signal generated by the GM-APD sensor is detected by the AQC, and the photon time-of-flight( TOF) is measured and converted to a digital signal output to achieve a better noise suppression and a higher detection sensitivity by the TDC. The ROIC circuit is fabricated by the CSMC 0. 5 μm standard CMOS technology. The array size is 8 × 8, and the center distance of two adjacent cells is 100μm. The measurement results of the chip showthat the performance of the circuit is good, and the chip can achieve 1 ns time resolution with a 250 MHz reference clock, and the circuit can be used in the array structure of the infrared detection system or focal plane array( FPA). 基于盖革模式(GM)雪崩光电二极管(GM-APD)探测阵列,设计了一种可用于红外3D成像的高性能红外传感读出电路(ROIC).该电路系统主要由主动淬火电路(AQC)、时间数字转换电路(TDC)和其他时序控制电路3个模块组成.AQC与TDC共同构成像素电路,在其余模块的配合下,由AQC电路检测GM-APD传感器产生的电流信号,TDC电路进行光子飞行时间(TOF)的计量,并转换为数字信号输出,从而实现更好的噪声抑制,更高的探测灵敏度.该电路采用CSMC 0.5μm标准CMOS工艺流片,阵列规模为8×8,像元中心距离100μm,芯片测试结果表明,电路功能良好,在250 MHz时钟驱动下,芯片可达到1 ns的时间分辨率,该电路可用于面阵结构红外探测系统或焦平面阵列.
出处 《Journal of Southeast University(English Edition)》 EI CAS 2016年第1期11-15,共5页 东南大学学报(英文版)
基金 The Natural Science Foundation of Jiangsu Province(No.BK2012559) Qing Lan Project of Jiangsu Province
关键词 infrared 3D(three-dimensional) imaging readout integrated circuit(ROIC) Geiger mode avalanche photodiode active quenching circuit(AQC) time-to-digital converter(TDC) 红外3D成像 读出电路 盖革-雪崩光电二极管 主动淬火电路 时间-数字转换电路
  • 相关文献

参考文献10

  • 1郑丽霞,吴金,时龙兴,奚水清,刘斯扬,孙伟锋.Active quenching circuit for a InGaAs single-photon avalanche diode[J].Journal of Semiconductors,2014,35(4):151-156. 被引量:3
  • 2Zheng Lixia, Yang Junhao, Liu Zhao, et al. Design and implementation of GM-APD array readout integrated cir- cuit for infrared 3D imaging[ C ]//International Symposi- um on Photoelectronic Detection and Imaging. Beijing, China, 2013:890744-1-890744-10. 被引量:1
  • 3Stoppa D, Gonzo L, Simony A. Scannerless 3D imaging sensors[C ]//IEEE International Workshop on Imaging Systems and Techniques. Niagara Falls, Canada, 2005: 58 - 61. 被引量:1
  • 4Lewis E N, Treado P J, Reeder R C, et al. Fourier transform spectroscopic imaging using an infrared focal plane array detector[ J ]. Analytical Chemistry, 1995, 67 (19) : 3377 -3381. 被引量:1
  • 5Itzler M A, Entwistle M, Krishnamachari U, et al. SWIR Geiger-mode APD detectors and cameras for 3D imaging [ C ]//Proc of SPIE. Baltimore, ML, USA, 2014 : 91140F-1 - 91140F-12. 被引量:1
  • 6Aull B F, Loomis A H, Young D J, et al. Three-dimen sional imaging with arrays of Geiger-mode avalanche photodiodes [C ]//Proc of SPIE. San Jose, CA, USA, 2004, 5353:105 - 116. 被引量:1
  • 7Aull B F, Bums J, Chen C, et al. Laser radar imager based on 3D integration of Geiger-mode avalanche photo- diodes with two SO1 timing circuit layers [C ]//2006 IEEE International Solid State Circuits Conference. 2006:1179 - 1188. 被引量:1
  • 8Itzler M A, Jiang X D, Entwistle M, et al. Advances in InGaAsP-based avalanche diode single photon detectors [J]. Journal of Modern Optics, 2011, 58(3/4): 174 - 200. 被引量:1
  • 9Vaidyanthan M, Joshi A. Xue S, et al. High perform ance ladar focal plane arrays for 3D range imaging[ C]// 2004 IEEE Proceedings of Aerospace Conference. Big Sky, MT, USA, 2004: 1776- 1781. 被引量:1
  • 10Niclass C, Soga M, Matsubara H, et al. A 100-m range 10-frame/s 340 × 96-pixel time-of-flight depth sensor in 0.18-μm CMOS[ J]. IEEE Journal of Solid-State Circuit, 2013, 48 (2) : 559 - 572. 被引量:1

二级参考文献8

  • 1Aull B F, Loomis A H, Young D J. Geiger-mode avalanche photodiodes for three-dimensional imaging. Lincoln Laboratory Journal, 2002,13(2): 355. 被引量:1
  • 2Tisa S, Zappa F, Tosi A. Electronics for single photon avalanche diode arrays. Sensors and Actuators A: Physical, 2007, 140(1): 113. 被引量:1
  • 3Gallivanoni A, Rech I, Ghioni M. Progress in quenching circuits for single photon avalanche diodes. IEEE Trans Nucl Sci, 2010, 57(6): 3815. 被引量:1
  • 4Zappa F, Ghioni M, Cova S, et al. An integrated active-quenching circuit for single-photon avalanche diodes. IEEE Trans Instrumentation Measurement, 2000, 49(6): 1167. 被引量:1
  • 5Zappa F, Tosi A, Dalla Mora A, et al. SPICE modeling of single photon Avalanche diodes. Sensors and Actuators, A: Physical, 2009,153: 197. 被引量:1
  • 6Zhao Feifei, Xu Yue, Guo Yufeng. A fully integrated single photon Avalanche diode detector in 130 nm CMOS technology. IEEE Conference on Digital Manufacturing and Automation (lCDMA), 2012: 54. 被引量:1
  • 7Mita R, Palumbo G. High-speed and compact quenching circuit for single-photon Avalanche diodes. IEEE Trans Nuci Sci, 2008, 57(3): 543. 被引量:1
  • 8Tisa S, Tosi A, Zappa F. Fully-integrated CMOS single photon counter. Opt Express, 2007, 15(6): 2874. 被引量:1

共引文献2

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部