MuhiStimSENSOR刺激器在肌间沟入路臂丛神经阻滞中的应用 被引量:3

Observation of MultiStim SENSOR Between Muscle Stimulator Ditch into the Application Effect of Brachial Plexus Block
原文传递
导出
摘要 目的观察MultiStimSENSOR刺激器在肌间沟入路臂丛神经阻滞中的应用效果。方法:120例拟行锁骨、肩部和肱骨近端区域手术的患者,随机分为神经体表定位组(I组)和神经刺激器组(Ⅱ组),2组均采用肌间沟路径。记录2组完成阻滞的穿刺次数,所需时阃,评价手术区域的阻滞和麻醉效果。结果:I组穿刺次数和操作时间明显少于Ⅱ组(P〈0.05),I组阻滞成功率、麻醉效果优良率明显高于Ⅱ组(P〈0.05),I组术后并发症发生率明显低于Ⅱ组(P〈0.05)。结论:使用MultiStimSENSOR刺激器的体表定住功能明显减少穿刺次数,缩短操作时间,提高穿刺成功率和麻醉效果优良率,降低并发症发生率。 Objective To observe MultiStim SENSOR between muscle stimulator ditch into the application effect of braehial plexusblock. Methods: 120 cases of proximal clavicle, shoulder and humerus quasi area surgery patients, randomly divided into nerve body po-sitioning group ( group I ) and nerve stimulator ( Ⅱ group), gully path between two groups all use muscle. Two sets of complete blockpuncture times, the time required, evaluate the efficacy of the area of the block and surgery anesthesia. Results: Ⅰgroup The Times andoperation time was significantly less than Ⅰ group ( P 〈 0.05 ), block of success rate, anesthesia was I group was obviously higher thanthat of II group ( P 〈 0.05), incidence of postoperative complications was lower than that in group lII group (P 〈 0.05). Conclu-sion : Using MUltiStimSENSOR stimulator positioning function of the body surface significantly decrease The Times of puncture and shortenthe operation time, improve the success rate of puncture and the rate of good anesthetic effect, reduce the incidence of complications.
出处 《中国伤残医学》 2016年第5期5-7,共3页 Chinese Journal of Trauma and Disability Medicine
关键词 肌间沟臂丛神经阻滞 体表定位 神经刺激器 Trench between muscle brachial plexus block Body surface location Nerve stimulator
  • 相关文献

参考文献7

二级参考文献20

  • 1徐仲煌,黄宇光,任洪智,叶铁虎,罗爱伦.神经刺激器定位神经阻滞在临床麻醉中的应用[J].临床麻醉学杂志,2001,17(5):278-279. 被引量:116
  • 2黄世清,王金桂,陈丽萍,李淑蓉.二针三分法在腋路臂丛神经阻滞中的应用[J].临床麻醉学杂志,2005,21(11):783-784. 被引量:1
  • 3徐小智,肖勤,常军,万明卿,胡小勇,吴华苗.超声引导下肌间沟法臂丛神经阻滞的临床研究[J].江西医药,2006,41(12):956-957. 被引量:10
  • 4徐恩多.局部解剖学.第4版.北京:人民卫生出版社,1997:25-49. 被引量:4
  • 5Marhofer P,Greher M, Kapral S. Ultrasound guidance in regional anaesthesia. Br J Anaesth, 2005, 94(1) :7-17. 被引量:1
  • 6Grossi P, Barbaglio C, Violini A, et al. Regional anesthesia update. Minerva Anestesiol, 2010,76 (8): 629-636. 被引量:1
  • 7Bowens C Jr, Gupta RK, O'Byrne WT, et al. Selective local anesthetic placement using ultrasound guidance and neuros timulation for infraclavicular brachial plexus block. Anesth Analg, 2010, 110(5):1480-1485. 被引量:1
  • 8Jeng CL, Rosenblatt MA. Intraneural injections and regional anesthesia: the known and the unknown. Minerva Anestesiol, 2011,77(1):54-58. 被引量:1
  • 9Gelfand HJ, Ouanes JP, Lesley MR, et al. Analgesic efficacy of ultrasound-guided regional anesthesia: a meta analysis. J Clin Anesth, 2011,23(2) :90-96. 被引量:1
  • 10Liu SS, YaDeau JT, Shaw PM, et al. Incidence of uninten tional intraneural injection and postoperative neurological complications with ultrasound-guided interscalene and supraclavicular nerve blocks. Anaesthesia, 2011,66(3) : 168-174. 被引量:1

共引文献46

同被引文献26

引证文献3

二级引证文献11

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部