依托勤丰220 kV GIS变电站工程,设计了3种不同形式的垂直出线构架方案,并从出线构架的占地空间、施工情况、安全性、经济性等方面对3种方案进行对比,提出适合工程应用的方案,达到既能满足工艺要求、保证结构安全可靠,又能节省占地、节约投资的目的。
There are three different design schemes of vertical outlet framework for 220 kV Qinfeng GIS sub- station project. The three schemes are compared in terms of space, construction, safety and economical effi- ciency. The paper presents a scheme applicable to engineering practice to meet technological requirements, guarantee structural safety, save space and reduce investment.
出处
《浙江电力》
2016年第2期36-39,共4页