摘要 干眼是指由于泪液的量或质的异常引起的泪膜不稳定和眼表面损害而致眼部不适的一类疾病。泪膜不稳定是引起干眼的一个重要原因。检测泪膜稳定性的传统方法是侵犯性泪膜破裂时间,具有一定的局限性。泪膜检测的新技术如泪膜镜、泪膜干涉成像仪、角膜活体共焦显微镜及角膜地形图摄像系统具有较小的侵犯性及较好的稳定性、重复性。该文对泪膜稳定性的几种检测方法的临床应用作一综述,以便更好地为干眼症的诊断、治疗提供可靠依据。 Dry eye occurs when there is inadequate tear volume or function resulting in an unstable tear film and ocular surface disease. Invasive tear film break-up time( BUT), which is the traditional examination of tear film stability, has certain limitations. New technologies, such as tearseope, tear film interferometry, in vivo eonfocal microscopy and oculus keratograph, have less invasion, better stability and repeatability. The examinations of tear fihn stability are reviewed in this paper to provide a reliable basis for the diagnosis and treatment of dry eye.
出处 《中国临床新医学》 2016年第2期175-178,共4页 CHINESE JOURNAL OF NEW CLINICAL MEDICINE
基金 广西卫计委科研课题(编号:Z2013398)
关键词 干眼 泪膜稳定性 泪膜破裂时间 Dry eye Tear film stability Tear film break-up time
  • 相关文献

参考文献24

二级参考文献47

  • 1张汗承,周祖廉,赵成荣,李燕先.干眼病记分分级和人工泪疗效评价的研究[J].眼科研究,1994,12(1):25-28. 被引量:119
  • 2陈问京,张污承.我国正常人和若干眼病中泪液乳铁蛋白的变化规律[J].中华眼科杂志,1989,25(5):292-295. 被引量:29
  • 3Li XM, Hu L, Hu J, et al. Investigation of dry eye disease and analy- sis of the pathogenic factors in patients after cataract surgery[ J]. Cor- nea, 2007, 26(9 Suppl 1 ) :16-20. 被引量:1
  • 4van Bijsterveld OP. Diagnostic tests in the sicca syndrome[ J]. Arch Ophthalmol, 1969,82(1) : 10-14. 被引量:1
  • 5Anon. Methodologies to diagnose and monitor dry eye disease:report of Diagnostic Methodology Subcommittee of the International Dry Eye WorkShop ( 2007 ) [ J ]. Ocul Surf, 2007,5 ( 2 ) : 108 -152. 被引量:1
  • 6Wen W, Wu Y, Chen Y, et al. Dry eye in patients with depressive and anxiety disorders in Shanghai [ J ]. Cornea, 2012, 31 ( 6 ) : 686-692. 被引量:1
  • 7Patel S, Boyd KE, Bums J. Age, stability of the preeomeal tear film and the refractive index of tears [ J ]. Cont Lens Anterior Eye, 2000, 23(2) : 44-47. 被引量:1
  • 8Benedetto DA, Clinch TE, Laibson PR. In vivo observation of tear dynamics using fluorophotometry[J]. Arch Ophthalmol, 1984, 102 (3) :410-412. 被引量:1
  • 9King-Smith PE, Fink BA, Fogt N, et al. The thickness of the human precorneal tear film: evidence from reflection spectra[ J]. Invest Oph- thalmol Vis Sci, 2000, 41 ( 11 ) : 3348-3359. 被引量:1
  • 10Zhuang H, Zhou X, Xu J. A novel method for pachymetry mapping of human precorneal tear film using Pentacam with fluorescin[ J]. Invest Oohthalmol Vis Sci. 2010, 51 (1) :156-159. 被引量:1

共引文献1663

同被引文献109

引证文献11

二级引证文献42

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部