期刊文献+

金属面复合夹芯板建筑体火灾蔓延特性 被引量:2

Investigation on the Fire Spread Characteristic of Metal Surface Sandwich Board Building
下载PDF
导出
摘要 按GB/T 25206《复合夹芯板建筑体燃烧性能试验》系列标准,设计并建造了彩钢复合夹芯板建筑体燃烧试验装置。针对岩棉、聚氨酯硬泡和聚苯乙烯泡沫作为芯材的彩钢复合夹芯板建筑体展开了大室法和小室法火灾蔓延特性研究,获得不同彩钢复合夹芯板的燃烧性能参数和建筑体的火灾蔓延特性参数。结果表明,B1级和B2级聚氨酯芯材彩钢复合夹芯板在火灾中通常能较好地维持结构稳定性,且未出现明显安全隐患。 The combustion test apparatus of color steel plate surfuce sandwich board building were designed and built according to GB/T 25206 Composite Sandwich Board Building Combustion Performance Test series stand- ard. The big chamber method and small room method fire spread characteristic research were conducted with rock wool, rigid polyurethane and polystyrene foam as the core material of the sandwich plate. The results showed that the flame retardancy levels B1 and B2 polyurethane core color steel plate surfuce sandwich p!ate usually could maintain the structural stability in the fire, and none of them had a significant safety problem.
作者 李建波
出处 《聚氨酯工业》 北大核心 2016年第1期33-36,共4页 Polyurethane Industry
基金 公安部科技信息化局应用创新计划项目
关键词 金属面夹芯板 彩钢复合夹芯板 聚氨酯硬泡夹芯板 聚苯乙烯夹芯板 燃烧测试 metal surface sandwich board color steel surfuce sandwich plate polyurethane foam sandwich board polystyrene sandwich panel combustion test
  • 相关文献

参考文献6

二级参考文献24

  • 1方禹声 朱吕民.聚氨酯泡沫塑料[M].北京:化学工业出版社,1996.. 被引量:8
  • 2GB/T23932-2009,建筑用金属面绝热夹芯板[s]. 被引量:3
  • 3GB/T9978.1-2008,建筑构件耐火试验方法第1部分:通用要求[s]. 被引量:6
  • 4解维益.金属面绝热用夹芯板保温隔热和力学性能研究[D].哈尔滨:哈尔滨工业大学,2008:41-50. 被引量:5
  • 5蔡为仑.复合材料设计[M].北京:科学出版社,1989. 被引量:12
  • 6GB 50016-2006,建筑设计防火规范[S]. 被引量:1267
  • 7Reissner E.Finite Deflections of Sandwich Plates[J].J Aeronaut Sci,1948;15(7):435-440. 被引量:1
  • 8GB50045-95(2005年版),高层民用建筑防火设计规范[S]. 被引量:2
  • 9GB/T9978.8-2008,建筑构件耐火试验方法第8部分:非承重垂直分隔构件的特殊要求[S]. 被引量:1
  • 10BS EN 14509--2006, Self-supporting double skin metal faced insula- ting panels--Factory made products Specifications[S]. 被引量:1

共引文献22