期刊文献+

Specific heat treatment of selective laser melted Ti-6AI-4V for biomedical applications 被引量:7

Specific heat treatment of selective laser melted Ti-6AI-4V for biomedical applications
原文传递
导出
摘要 The ductility of as-fabricated Ti-6AI-4V fails far short of the requirements for biomedical titanium alloy implants and the heat treatment remains the only applicable option for improvement of their mechanical properties. In the present study, the decomposition of as-fabricated martensite was investigated to provide a general understanding on the kinetics of its phase transformation. The decomposition of as- fabricated martensite was found to be slower than that of water-quenched martensite. It indicates that specific heat treatment strategy is needed to be explored for as.fabricated Ti-6AI-4V. Three strategies of heat treatment were proposed based on different phase transformation mechanisms and classified as subtransus treatment, supersolvus treatment and mixed treatment. These specific heat treatments were conducted on selective laser melted samples to investigate the evolutions of microstructure and mechanical properties. The subtransus treatment leaded to a basket-weave structure without changing the morphology of columnar prior β grains. The supersolvus treatment resulted in a lamellar structure and equiaxed β grains. The mixed treatment yielded a microstructure that combines both features of the subtransus treatment and supersolvus treatment. The subtransus treatment is found to be the best choice among these three strategies for as.fabricated Ti-6AI-4V to be used as biomedical implants. The ductility of as-fabricated Ti-6AI-4V fails far short of the requirements for biomedical titanium alloy implants and the heat treatment remains the only applicable option for improvement of their mechanical properties. In the present study, the decomposition of as-fabricated martensite was investigated to provide a general understanding on the kinetics of its phase transformation. The decomposition of as- fabricated martensite was found to be slower than that of water-quenched martensite. It indicates that specific heat treatment strategy is needed to be explored for as.fabricated Ti-6AI-4V. Three strategies of heat treatment were proposed based on different phase transformation mechanisms and classified as subtransus treatment, supersolvus treatment and mixed treatment. These specific heat treatments were conducted on selective laser melted samples to investigate the evolutions of microstructure and mechanical properties. The subtransus treatment leaded to a basket-weave structure without changing the morphology of columnar prior β grains. The supersolvus treatment resulted in a lamellar structure and equiaxed β grains. The mixed treatment yielded a microstructure that combines both features of the subtransus treatment and supersolvus treatment. The subtransus treatment is found to be the best choice among these three strategies for as.fabricated Ti-6AI-4V to be used as biomedical implants.
出处 《Frontiers of Materials Science》 SCIE CSCD 2015年第4期373-381,共9页 材料学前沿(英文版)
基金 Acknowledgements The authors are grateful for the financial support from the National Natural Science Foundation of China (Grant Nos. 51361130032 and 51472139) and the Doctor Subject Foundation of the Ministry of Education of China (Grant No. 20120002130002).
关键词 titanium alloy selective laser melting (SLM) heat treatment microstruc-ture mechanical property titanium alloy selective laser melting (SLM) heat treatment microstruc-ture mechanical property
  • 相关文献

参考文献27

  • 1Niinomi M. Recent metallic materials for biomedical applications. Metallurgical and Materials Transactions A: Physical Metallurgy and Materials Science, 2002, 33(3): 477-486. 被引量:1
  • 2Yang X, Richard Liu C. Machining titanium and its alloys. Machining Science and Technology, 1999,3: 107-139. 被引量:1
  • 3Murr L E, Quinones S A, Gaytan S M, et al. Microstructure and mechanical behavior of Ti-{iAI-4V produced by rapid-layer manufacturing, for biomedical applications. Journal of the Mechanical Behavior of Biomedical Materials, 2009, 2(1): 20-32. 被引量:1
  • 4Vandenbroucke B, Kruth J P. Selective laser melting of biocompatible metals for rapid manufacturing of medical parts. Rapid Prototyping Journal, 2007, 13(4): 196-203. 被引量:1
  • 5Thijs L, Verhaeghe F, Craeghs T, et al. A study of the microstructural evolution during selective laser melting of Ti- 6AI-4Y. Acta Materialia, 2010, 58(9): 3303-3312. 被引量:1
  • 6Kruth J P, Badrossamay M, Yasa E, et al. Part and material properties in selective laser melting of metals. Proceedings of the 16th International Symposium on Electromachining, 2010. 被引量:1
  • 7Hollander D A, von Walter M, Wirtz T, et al. Structural, mechanical and in vitro characterization of individually structured Ti-6AI-4V produced by direct laser forming. Biomaterials, 2006, 27(7): 955-963. 被引量:1
  • 8Rafi H K, Karthik N V, Gong H, et al. Microstructures and mechanical properties of Ti6Al4V parts fabricated by selective laser melting and electron beam melting. Journal of Materials Engineering and Performance, 2013, 22: 1-12. 被引量:1
  • 9ASTMFI472-08el. Standard specification for wrought titanium- 6aluminum-4vanadium alloy for surgical implant applications (UNS R56400), 2008. 被引量:1
  • 10ASTMFII08-04. Standard specification for titanium-oaluminum- 4vanadiurn alloy castings for surgical implants (UNS R56406), 2009. 被引量:1