针对某电厂660 MW直流锅炉点火期间出现的等离子燃烧器筒内结焦、筒外烧损的现象,在深入分析结焦、烧损原因的基础上,提出有效预防措施。燃烧器后期运行状况良好,以此为同类型超超临界锅炉稳定运行提供参考。