期刊文献+

人工唾液和乳酸对Vitallium 2000钴铬钼合金卡环疲劳强度影响的研究 被引量:3

The effect of artificial saliva and lactic acid on the fatigue strength of Vitallium 2000 Co-Cr-Mo alloy clasps
下载PDF
导出
摘要 目的探讨人工唾液和乳酸对Vitallium 2000钴铬钼合金卡环疲劳强度的影响。方法用成品卡环蜡型制作Vitallium 2000钴铬钼合金卡环15个,分为3组,分别在空气、人工唾液和乳酸溶液中进行测试。自动记录初始载荷强度和疲劳失效前的载荷循环次数,扫描电镜分析疲劳裂纹。结果 Vitallium 2000钴铬钼合金卡环在不同测试条件下的初始载荷强度无差异(P>0.05)。在空气中的循环次数最高,在乳酸溶液中的循环次数最低。SPSS软件分析表明3组之间的疲劳强度有显著性差异(P<0.01)。结论人工唾液和乳酸溶液均使Vitallium 2000钴铬钼合金卡环的疲劳强度下降。 Objective To study the effect of artificial saliva and lactic acid solution on the fatigue strength of Vitallium 2000 Co-CrMo alloy clasps. Methods 15 clasp specimens of Vitallium 2000 Co-Cr-Mo alloy clasps were made from prefabricated clasp wax,and were divided into 3 groups. Specimens were tested in air,artificial saliva and lactic acid solution. Initial loading force and loading cycle numbers before fracture were registered automatically,and fracture flaws were examined with a scanning electron microscope( SEM). Results Initial loading force of Vitallium 2000 Co-Cr-Mo alloy clasps didn't differ significantly in three test conditions( P〈0. 05). The tested clasps had the highest loading number cycles in air and the lowest ones in lactic acid solution. Fatigue strength analysis of SPSS software showed a significant difference among three groups( P〈0. 01). Conclusion Both artificial saliva and lactic acid solution reduce the fatigue strength of Vitallium 2000 Co-Cr-Mo alloy clasps.
出处 《口腔医学》 CAS 2016年第1期34-36,43,共4页 Stomatology
关键词 VITALLIUM 2000钴铬钼合金 疲劳强度 卡环 Vitallium 2000 Co-Cr-Mo alloy fatigue strength clasp
  • 相关文献

参考文献9

二级参考文献40

  • 1冯海兰.口腔修复学[M].北京:北京大学医学出版社,2007:168-180. 被引量:9
  • 2Karlsen K, Owall B. Construction proposals for vitallium prostheses [J]. Quintessenz Zahntech, 1975, 1 (2) : 19-24. 被引量:1
  • 3Taylor RM. Vitallium removable overlays for deep overbite-ease report[J]. N Z Dent J, 1985, 81(363):28-29. 被引量:1
  • 4Bridgeport DA, Branfley WA, Herman PF. Cobalt-chromium and nickel-chromium alloys for removable prosthodontics. Part 1: Mechanical properties[J]. J Prosthodont, 1993, 2(3):144-150. 被引量:1
  • 5Pienkos TE, Morris WJ, Gronet PM, et al. The strength of multiple major connector designs under simulated functional loading [J]. J Prosthet Dent, 2007, 97 (5):299-304. 被引量:1
  • 6Knapp JG, Shotwell JL, Kotowicz WE. Technique for recording dental casturveyor relations[J]. J Prosthet Dent, 1979, 41 (3): 352-354. 被引量:1
  • 7Knapp JG, Small IA. Fixed mandibular complete denture prostheses supported by mandibular staple bone plate implant[J]. J Prosthet Dent, 1990, 63 (1) : 73-76. 被引量:1
  • 8Sato Y, Abe Y, Yuasa Y, et al. Effect of friction coefficient on Akers clasp retention. J Prosthet Dent, 1997, 78( 1 ) : 22-27. 被引量:1
  • 9Goto T. The clinics of Konus Telescope. Tokyo: Quintessence, 1991 : 14-20. 被引量:1
  • 10平沼谦二,陈吉华.部分活动义齿技术[M].西安:陕西科学出版社,2001:107-111. 被引量:1