摘要 试验采用“湿帘-风机”系统对妊娠猪舍在高温季节的降温效果进行了分析,探讨高温季节不同降温模式对妊娠猪舍的降温效果。结果表明:舍外热空气经湿帘后,温度可降低7.06℃,湿度上升37.20个百分点。当湿帘与风机距离相同时,风机安装于横墙或纵墙不影响降温效果。距离湿帘越远,舍内温度越高,湿度越低,风机口与湿帘处的温湿度差分别达1.88℃、8.66个百分点。连续监测该猪舍环境参数,舍内温度均在25.33~29.17℃范围之间,且受外界温度变化影响较小;二氧化碳、氨气、硫化氢气体浓度均在各标准范围内。研究结果表明,高温季节采用“湿帘-风机”降温系统,可改善妊娠猪舍内环境。 Cooling Pad-fan system was used to investigate the cooling effect in pregnant sow pen during hot season in the study. The results showed that the temperature indoor was reduced by 7.06 ℃ and the humidity increased by 37.20 percentage, and the cooling effect was not influenced by the position of the fan. Meanwhile, the temperature indoor was increased with the distance of the pad. The humidity indoor was decreased with the distance of the pad. The differences of temperature and humidity between the fan and the pad reached 1.88 ℃ and 8.66 percentage, respectively. Continuous monitoring displayed the tem- perature indoor between 25.33℃-29.17℃, which was not influenced significantly by outdoor temperature. The concentrations of CO2, H2S and NH3 were in the range of standards. Therefore, the system can improve the indoor environment obviously.
出处 《家畜生态学报》 北大核心 2016年第1期46-52,共7页 Journal of Domestic Animal Ecology
基金 四川省支撑计划(2013NZ0030) 四川生猪产业技术体系创新团队(SCCXTD-005) 国家生猪产业技术体系(CAR-36) 四川省科技支撑计划项目(2013NZ0056)
关键词 湿帘 风机 温度 湿度 二氧化碳 硫化氢 氨气 cooling pad fan temperature humidity CO2 H2 S NH3
  • 相关文献

参考文献13

  • 1安立,龙效梅,吴中红,黄锡霞.西安地区集约化蛋鸡场的环境与生产[J].甘肃畜牧兽医,1997,27(5):1-3. 被引量:11
  • 2Steven J Hoff. The Environment in Swine Housing [J]. Fact-sheet,2009(4) :1-7. 被引量:1
  • 3Btische W, Franke G, Haidn B, et al. GLG-Arbeitsunterlage [M]. Frankfurt am Main: GLC~Arbeitsunterlage, 2003: 11- 12. 被引量:1
  • 4H Van den Weghe, W Btische, Peter Cremer Grefrath,et al. Berechnungs- und Planungsgrundlagen ftir das Klima in ges- chlossenen St~llen[ M]. Berlin : AEL AEL -Heft, 2007 : 1-20. 被引量:1
  • 5NRC. Nutrient Requirement of Swine[M]. 10 ed. Washing- ton:DC, National Academy Press, NRC, 1998: 90-120. 被引量:1
  • 6汪开英,苗香雯,崔绍荣,Coen M Hogenboom,R.Geers.猪舍环境温湿度对育成猪的生理及生产指标的影响[J].农业工程学报,2002,18(1):99-102. 被引量:57
  • 7Banhazi T M, Rutley D L, Pitchford W S. Identification of risk factors for sub-optimal housing conditions in Australian piggeries: Part 4. Emission factors and study recommendations [J]. J Agric Saf Health,2008,14(1) ..53-69. 被引量:1
  • 8Kim K Y, long K H, Kim H T, et al. Quantification of am- monia and hydrogen sulfide emitted from pig buildings in Korea[J]. J Environ Manage, 2008,88(2) : 195-202. 被引量:1
  • 9张文海.对风机风量计算公式的认识[J].微电机,2007,40(10):82-83. 被引量:8
  • 10W Bt~scher, S Fritzsche, H Van den Weghe, et al. Lti{tung in Schweinest~illen[M]. Darmstadt : KTBL-Schrift, 2002 : 1-9. 被引量:1

二级参考文献32

  • 1艾地云.常温与高温季节肥育猪主要生产性能的影响[J].养猪,1996,(11). 被引量:1
  • 2Krupa S V. Effects of atmospheric ammonia (NH3) on terrestrial vegetation: a review[J]. Environ Pollut, 2003, 124(2): 179-221. 被引量:1
  • 3Zhang Y, Dore A J, Ma L, et al. Agrieuhural ammonia emissions inventory and spatial distribution in the North China Plain[J]. Environ Pollut, 2010, 158(2): 490-501. 被引量:1
  • 4Misselhrook N G. Surviving in mixed practice[J]. Vet Rec, 2000, 147(21): 612. 被引量:1
  • 5Banhazi T M, Rutley D L, Pitchford W S. Identification of risk factors for suboptimal housing conditions in Australian piggeries: Part 4. Emission factors and study recommendations[J]. J Agric Saf Health, 2008, 14(1) : 53-69. 被引量:1
  • 6Kim K Y, Jong K H, Kim H T, et al. Quantification of ammonia and hydrogen sulfide emitted from pig buildings in Kore a[J]. J Environ Manage, 2008, 88(2): 195-202. 被引量:1
  • 7Wang C, Li B,Zhang G, et al. Model estimation and measurement of ammonia emission from naturally ventilated dairy cattle buildings with slatted floor designs[J]. J Air Waste Manag Assoc, 2006,56(9): 1 252-1259. 被引量:1
  • 8Sun G, Guo H,Peterson J. Seasonal odor, ammonia, hydro gen sulfide, and carbon dioxide coneentrations and emissions from swine grower finisher rooms[J]. J Air Waste Manag Assoc, 2010, 60(4): 471-480. 被引量:1
  • 9Lemay S P, Chenard L, Gonyou H W, et al. A two airspacebuilding design to reduce odor and ammonia emissions[J]. Applied Engineering in Agriculture, 2010, 105(4): 455-465. 被引量:1
  • 10Groenestein C M, Van Faassen H G. Volatilization of ammonia, nitrous oxide and nitric oxide in deeplitter systems for fattening pigs[J]. Journal of Agricultural Engineering Research, 1996, 65(4) : 269-274. 被引量:1

共引文献104

同被引文献129

引证文献16

二级引证文献57

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部