期刊文献+

可溯源冲击电压校准器特性研究 被引量:2

Performance analysis for a traceable impulse voltage generator
下载PDF
导出
摘要 介绍一种可溯源的冲击电压校准器,该校准器可输出IEC 60060-1——2010《高电压试验技术第一部分:一般定义和试验要求》中所规定的标准雷电全波、雷电操作波等4种时间参数波形,可作为标准波源对数字记录仪及冲击峰值表进行校准。该校准器可通过理论分析的方式溯源至各元器件的国家标准,其输出电压峰值不确定度<0.1%,时间参数不确定度<0.5%,可满足实际应用中对冲击电压峰值表及冲击测量用数字记录仪的幅值及时间测量参数校准的需求,具有很好的实用性及较高的推广价值。 This paper introduces a traceable impulse voltage generator which can generate standard lighting impulse and switch impulse waveforms according to IEC 60060 1:2010. It is used to calibrate the time parameters and peak value for digital recorder and digital peak value voltmeter. The estimated uncertainty for the impulse peak value is less than 0.1% and for time parameters, lass than 0.5%. It can be traced to national compnent standard by theoretical analysis. It can satisfy the parameters calibration requirements of digital voltmeter and digital recorder used for measuring lighting waveform. It is of great practical use and can be used widely in impulse measurement calibration.
出处 《中国测试》 CAS 北大核心 2016年第1期31-34,共4页 China Measurement & Test
关键词 可溯源 标准波源 数字记录仪 冲击峰值表 traceable standard waveform generator digital recorder peak value volmeter
  • 相关文献

参考文献10

二级参考文献10

共引文献13

同被引文献24

引证文献2

二级引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题