期刊文献+

SCR脱硝系统最低连续喷氨温度的研究 被引量:27

Study on Minimum Continuous-Operation Temperature of SCR System
下载PDF
导出
摘要 目前国内选择性催化还原(SCR)脱硝机组普遍存在低负荷停止喷氨的问题,脱硝装置停运工况所对应的烟气温度称之为最低连续喷氨温度。出于技术保护的目的,以往引进国外技术的催化剂制造商得不到此温度的计算方法。为此,从硫酸氢铵(NH_4HSO_4)的生成机理出发,分析了NH_4HSO_4的结露过程,并结合催化剂的微孔毛细管冷凝现象,提出了一种计算最低连续喷氨温度的方法,该方法计算结果与工程实践有很好的耦合度。同时,根据烟气成分、脱硝效率、NO_x入口浓度对最低连续喷氨温度的影响,结合运行经验,提出了"欠氨运行"概念,用以指导工程实践和脱硝系统的运行。 Currently, most SCR systems cannot be operated under low loading conditions due to the low temperature of the flue gas. The temperature threshold at which the SCR is no longer operable is defined as the minimum continuous-operation temperature. However, the calculation method of this temperature is unavailable from the foreign catalyst technology supplier for confidentiality reasons. Therefore, this paper proposes a method to calculate the minimum continuous-operation temperature based on the ammonium bisulfate(ABS) generating mechanism and dewing process as well as the theory of capillary condensation. The calculation result of this method shows good consistency with the practical data. In addition, considering the influences of flue gas composition, de-NOx efficiency, and inlet NOx concentration on the minimum continous-operation temperature, this paper also puts forward the concept of inadequate operation to guide the daily operation of the SCR system for power plants.
出处 《中国电力》 CSCD 北大核心 2016年第1期146-150,共5页 Electric Power
关键词 火电厂 烟气脱硝 选择性催化还原(SCR) 催化剂 NH4HSO4 最低连续喷氨温度 thermal power plant, flue gas denitration SCR catalyst ammonium bisulfate (ABS) minimum continuous-operation temperature
  • 相关文献

参考文献13

二级参考文献94

共引文献369

同被引文献197

引证文献27

二级引证文献128

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部