摘要
对于传统功率计算不适合C2,C3类压缩机在临界参数附近工作时的问题,通过对比态原理和一系列实际气体状态方程,推导出绝热指数k值的公式并推出更具普遍性的功率计算关系式,并通过Matlab编写出计算程序,成功运用到C2,C3类压缩机的功率求解上。
In consideration of that the traditional power calculation is not suitable for the C2,C3 compressor near the critical parameters problems,we introduced a formula of adiabatic index k and a more general power calculation formula through a series of real gas state equation and the theorem of corresponding states. And the power of C2 C3 compressor can be successfully solved out by the Matlab calculation program.
出处
《武汉理工大学学报(信息与管理工程版)》
CAS
2015年第6期832-836,共5页
Journal of Wuhan University of Technology:Information & Management Engineering
基金
武汉高新技术开发基金资助项目(2014010101010010)