期刊文献+

腔内心电图联合超声探查在PICC尖端定位中的应用研究 被引量:20

Application of intravenous electrocardiogram combined with ultrasonic test in the peripherally inserted central catheter tip positioning
下载PDF
导出
摘要 目的:探讨自制转换器显示腔内心电图联合超声探查在经外周静脉置入中心静脉导管(peripherally inserted central catheter,PICC)尖端定位中应用效果以及P波定位代替X线检测的可能性。方法:选择符合入组条件的PICC置管患者1 028例,按照住院号尾数的奇偶分为实验组(n=513)和对照组(n=515)。实验组通过自制转换器把体表心电图转化为腔内心电图,然后通过观察P波变化和超声探查来检测尖端位置,对照组通过超声探查来检测导管尖端位置,置管后2组患者均拍X线片。记录两组患者的尖端到位情况、异位情况以及实验组P波预测与X线检测结果的一致程度。结果:实验组尖端到位率高于对照组,差异有统计学意义(χ-2=20.475,P=0.000);对减少不同部位的异位率有统计学意义(P﹤0.05),但对锁骨下反折以及腋静脉的异位率的差异无统计学意义(χ-2=0.140,P=0.708;χ-2=2.997,P=0.083);实验组P波预测尖端到位情况与X线检测结果的一致性程度较好(κ=0.877,P=0.000)。结论:应用自制转换器显示腔内心电图联合超声探查可以提高置管成功率,值得在临床推广,对于有特征性P波的患者,腔内心电图P波定位对X线检测定位具有替代效果。 Objective:To determine the application efficacy of the self-made converter displaying the intravenous electrocardiogram combined with ultrasonic test and to explore the possibility of P waves positioning instead of X-ray test in determining terminal tip location when inserting a peripherally inserted central catheter(PICC). Methods:Totally 1 028 patients inserted with PICCs were assigned to the experimental group(n=513) and control group(n=515) according to the admission number. In experiment group,surface electrocardiogram was converted to endocaridal electrogram by the self-made converter;then the tip location was determined by P wave changes and ultrasonography examination. In control group,the tip location was determined by ultrasonography examination. Finally,X-ray was used to confirm the tip location of all the patients. The tip location,ectopic situation,as well as the congruence of P wave prediction and X-ray test were recorded. Results:Tip in-place rate of the experimental group was significantly higher than that of control group(χ-2=20.475,P=0.000). There was no significant difference in ectopic rate of subclavian vein reflexion and the axillary vein between the two group(χ-2=0.140,P=0.708;χ-2=2.997,P=0.083). The congruence rate of P waves prediction and the results of Xray test were good(κ=0.877,P=0.000). Conclusion:Application of self-made converter displaying the intravenous electrocardiogram combined with ultrasonic test can increase the success rate of PICC catheterization,therefore worth clinical promotion. For patients with characteristic P wave,P wave positioning can replace X-ray test in determining terminal tip location during inserting PICC.
出处 《重庆医科大学学报》 CAS CSCD 北大核心 2015年第12期1576-1581,共6页 Journal of Chongqing Medical University
关键词 腔内心电图 自制转换器 超声探查 经外周静脉置入中心静脉导管 intravenous electrocardiographic ultrasonic testing tip location peripherally inserted central catheter
  • 相关文献

参考文献15

  • 1Johnston A J, Bishop SM, Martin L, et al.Defining peripherally in- serted, 2013,50 ( 8 ) : 749 -752. 被引量:1
  • 2Hostetter R,Nakasawa N,Tompkins K,et al.Precision in central venous catheter tip placement:a review of the literature[J]Joumal of the Association for Vascular Access, 20 1 0,15 ( 3 ) : 112-125. 被引量:1
  • 3Witthayapraphakom L, Khositseth A, Jiraviwatana T, et al.Appro- pilate length and position of the central venous catheter insertion via right internal jugular vein in children [J].Indian Pediatr, 2013,50 ( 8 ) : 749-752. 被引量:1
  • 4York N.The importance of ideal central venous access device tip position[J].British Journal of Nursing,2012,21 (s21) : 19-24. 被引量:1
  • 5李康明,鞠云鹤,刘燕,张玲玲,秦继勇.经外周插管的中心静脉导管移位胸外侧静脉一例[J].临床误诊误治,2007,20(4):63-64. 被引量:12
  • 6Rupp SM,Apfelbaum JL,Blitt C,et al.Practice guidelines for cen-tral venous access:a report by the American Society of Anesthesiolo- gists Task Force on Central Venous Access[J].Anesthesiology, 2012,116(3):539. 被引量:1
  • 7周莲清,谌永毅,王佳丽,刘高明,沈波涌,卿利敏.心房内心电图引导PICC尖端定位方法的临床应用研究[J].护士进修杂志,2013,28(22):2021-2023. 被引量:55
  • 8姚辉,宋敏,刘玉莹.静脉内心电图引导PICC尖端定位的临床研究[J].中华护理杂志,2011,46(8):748-750. 被引量:96
  • 9Johnston A J, Holder A,Bishop SM, et al.Evaluation of the sherlock 3CG tip confirmation system on peripherally inserted central catheter malposition rates[J].Anaesthesia, 2014,69 ( 12 ) : 1322-1330. 被引量:1
  • 10钱丰..超声监测下内测量法对PICC导管尖端定位技术的临床应用研究[D].苏州大学,2013:

二级参考文献51

共引文献169

同被引文献176

引证文献20

二级引证文献118

相关作者