摘要 目的 :检测分析国产血培养瓶对细菌和真菌培养检测能力。方法 :将已知菌株的菌悬液稀释成不同浓度,定量加入3种不同的血培养瓶中,检测其细菌和真菌的生长情况。结果:国产血培养瓶的可检测浓度范围为1-108cfu/m L;国产血培养瓶报警时间比法国进口血培养瓶、美国进口血培养瓶均长,差异存在统计学意义(P值均为0.021)。结论 :国产血培养瓶基本可达到临床检测要求,对细菌和真菌的检出能力不亚于进口的血培养瓶,但缺点是报警时间比进口瓶长。 Objective: To investigate the detection capability of Dier(Zhuhai) blood culture bottle for bacteria and fungi. Methods: The suspension of known bacterial and fungi strains were diluted to different concentrations and added into Dier blood culture bottle and other two kinds of blood culture bottle(bio Merieux Bact/ALERT blood culture bottle and BD blood culture bottle). Results: The detectable concentatrion range of bacteria and fungi in Dier blood culture bottle was 1-108cfu/m L; the alarm time of Dier blood culture bottle was singnificantly longer than those of bio Merieux Bact/ALERT blood culture bottle(P =0.021) and BD blood culture bottle(P =0.021). Conclusions: Dier blood culture bottle could meet the needs of detection of bacteria and fungi, and the detection capability for bacteria and fungi is no less than that of the imported blood culture bottles, however, the alarm time of Dier blood culture bottle is longer than those of the imported blood culture bottles.
出处 《诊断学理论与实践》 2015年第5期461-463,共3页 Journal of Diagnostics Concepts & Practice
关键词 血培养瓶 血培养系统 细菌 真菌 Blood culture bottle Blood culture system Bacteria Fungi
  • 相关文献

参考文献7

二级参考文献47

  • 1刘恭植.血培养研究的进展[J].临床检验杂志,1996,14(1):48-50. 被引量:14
  • 2张军民,周贵民.厌氧菌血培养仍是值得重视的问题[J].中华检验医学杂志,2005,28(10):979-980. 被引量:23
  • 3周贵民,张军民.血培养方法研究进展[J].中华医学检验杂志,1996,19(6):331-333. 被引量:31
  • 4徐修礼,杨佩红,孙怡群,樊新.深部真菌感染的菌群分布及耐药性[J].中华医院感染学杂志,2007,17(3):349-351. 被引量:50
  • 5Benjamin JG, Lynn LH, Duane R. Effect of inoculum size on detection of candida growth by the BACTEC 9240 automated blood culture system using aerobic and anaerobic media[J]. J Clin Mierobiol,2005,43(1) :433-435. 被引量:1
  • 6Helene FH, Bernadette L, Herve P, et al. Use of the BACTEC 9240 system with Mycosis-IC/F blood culture bottles foe detection of fungemia[J]. J Clin Microbiol,2004,42:1855 -1856. 被引量:1
  • 7NCCLS. Reference method for broth dilution antifungal susceptibility testing of yeasts[S]. Approved standard. M27-A2. NCCLS, 2002. 被引量:1
  • 8Vandijck DM, Depaemelaere M, I-abeau SO, et al. Daily cost of antimierobial therapy in patients with intensive care unitacquired,laboratory-confirmed bloodstream infeetion[J]. Int J Antimierob Agents, 2008,31 (2) : 161-165. 被引量:1
  • 9Wilson JR, Limaye AP. Anaerobic bacteremia: the yield of positive anaerobic blood cultures: patient characteristics and potential risk factors[J]. Clin Chem Lab Med, 2003,41 (3) : 293-297. 被引量:1
  • 10Zahar JR, Farhat H, Chacharty E, et al. Incidence and clinical significance of anaerobic baeteraemia in cancer patients: a 6- year retrospective study[J]. Clln Microbial Infect, 2005, 11 (9) :724-729. 被引量:1

共引文献53

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部