期刊文献+

湿热地区家用空调冷凝水回收研究 被引量:12

Energy utilization of condensate water from air conditioner in hot and humid areas
下载PDF
导出
摘要 针对湿热地区家用空调冷凝水无序排放和冷量损失问题,提出了一种冷凝水与压缩机排气管进行大温差换热的方法,该方法可以减缓冷凝水的流动,增加冷凝水与压缩机排气管的换热面积和换热时间,实现空调冷凝水对高温制冷剂的预冷却。实验结果表明:虽然空调冷凝水量有限,但冷凝器出现了1.1~2.0℃的过冷现象,系统的制冷量和COP分别提高了0.93%和1.7%;冷凝水蒸发形成的水蒸气能够及时被冷凝器的风机带走,解决了家用空调冷凝水的无序排放问题。 In order to solve the problems of disorderly discharge of condensed water and cold loss, proposes a large temperature difference heat transfer method between the condensed water and the discharge pipe of compressor. It can not only decrease the movement of condensed water, but also increase the heat transfer area and time, which achieves precooling of the high temperature refrigerant in the outlet of compressor. The results show that although the condensed water is limited, the super cooling temperature is about 1.1 to 2.0 ℃ in the condenser, and the COP and cooling capacity increase by 0.93% and 1.7%, respectively. The water vapor evaporated can be easily carried away by the condenser fan, which solves the disorderly discharge problem of condensed water.
机构地区 西安交通大学
出处 《暖通空调》 北大核心 2015年第12期53-56,21,共5页 Heating Ventilating & Air Conditioning
基金 国家自然科学基金资助项目(编号:51478386)
关键词 湿热地区 家用空调 冷凝水 回收 蒸发冷却器 大温差换热 压缩机排气管 hot and humid area, household air conditioner, condensate water, recovery, evaporativecooler, heat exchange with large temperature difference, discharge pipe of compressor
  • 相关文献

参考文献8

二级参考文献26

共引文献110

同被引文献76

引证文献12

二级引证文献24

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部