某畜禽屠宰污水厂产生恶臭气体的主要污染源为格栅井、细格栅及隔油沉淀池、气浮机、水解酸化池、污泥池、脱水机房等,对这些构筑物进行了加盖封闭,对臭气分散收集后采用生物除臭法处理,达到了较好的除臭效果。
The odorous gas sources in slaughterhouse wastewater treatment plant are grid well, fine grille, oil separation and sedimentation tank, flotation machine, hydrolytic acidification tank, sludge tank, dehydration machine room and so on. These treatment units were covered, the odorous gas was collected and treated by biological deodorization, and the excellent deodorization effect was achieved.
出处
《中国给水排水》
CAS
CSCD
北大核心
2015年第22期70-73,共4页
China Water & Wastewater
基金
国家科技支撑计划项目(2012BAB18B03
2014BAC02B01)
关键词
屠宰污水厂
恶臭气体
生物除臭
工程设计
slaughterhouse wastewater treatment plant
odorous gas
biological deodorization
project design