离子色谱法测量发电厂水汽系统蒸汽钠离子的不确定度评定 被引量:5

Uncertainty Evaluation of Ion Chromatography in Trace Sodium Ion Measurement of Power Plant Water & Steam System
下载PDF
导出
摘要 为确保检测数据的准确性和可靠性,有必要对测定方法进行不确定度评定。根据测量不确定度评定方法,分析了离子色谱仪测量电厂水汽系统蒸汽钠离子的主要不确定度来源,明确了各不确定度分量的大小。评定结果表明:离子色谱仪测量电厂水汽系统蒸汽钠离子不确定度的主要来源由标准工作曲线拟合产生,而测量重复性、加标回收率及标准工作溶液的配制也是引入不确定度的因素。 In order to ensure the accuracy and reliability of the test data, it is necessary to evaluate the uncertainty of ion chromatography. Using the uncertainty evaluation methods, this paper analyzes and quantifies the main uncertainty sources of trace sodium in the power plant water and steam system measured by ion chromatography. The outcome of the uncertainty evaluation indicates that the uncertainty in the trace sodium measurement mainly results from the standard curve fitting. Other affecting factors include the repeatability, recovery and preparation of the standard solution.
作者 潘珺
出处 《中国电力》 CSCD 北大核心 2015年第11期34-38,共5页 Electric Power
关键词 离子色谱仪 不确定度 发电厂 水汽系统 钠离子 ion chromatography uncertainty power plant water and steam system sodium