摘要
本文主要介绍糖厂利用低压电容补偿装置控制高压无功补偿的成功应用,是基于广西来宾东糖凤凰有限公司季节性生产,在设备检修期间用电负荷低,用电功率因数低,仅用低压电容无法满足供电用电功率因数的要求,用高压电容补偿时因高压电容容量过大又出现过补的情况,提出低压反补高压无功损耗方案,在实施改造后取得较好效果,值得推广应用。
This paper mainly introduces the successful application of sugar mill with low voltage capacitor compensation de- vice control of high voltage reactive power compensation,this paper is the production of seasonal Guangxi guests Eastern sugar Co., based in Phoenix, equipment maintenance during the low electricity load, power factor is low, unable to meet only with low voltage capacitor power factor requirements for power supply, with high pressure capacitance compensation due to high voltage capacitor capacity is too large and appeared the situation, put forward voltage reverse complement of high volt- age reactive power loss scheme, has achieved good effect in the implementation of the transformation, it is worth populariza- tion and application.
出处
《广西糖业》
2015年第5期40-42,共3页
Guangxi Sugar Industry
关键词
糖厂用电
功率因数
improve
sugar
power factor