期刊文献+

氟-18正电子发射型断层扫描在植入式心血管电子装置感染诊断中的应用 被引量:3

Application of fluorine-18 positron emission tomography and computed tomography in diagnosis of cardiovascular implantable electronic device Infection
原文传递
导出
摘要 目的探讨氟-18正电子发射型断层扫描(18F PET-CT)在植入式心血管电子装置(CIED)感染病例诊断中的应用价值。方法入选2013年1月至2014年6月就诊于本中心初步诊断为CIED感染的患者。对于根据症状、常规血培养、心脏超声检查无法明确诊断者,进一步接受PET-CT检查,以明确诊断及分型。然后,根据诊断分别进行针对性治疗,随访一年,观察PET-CT对CIED感染诊断的准确率。结果 2013年1月至2014年6月就诊于本中心初步诊断为CIED感染的患者共227例。其中,10例患者伴有明显症状,但通过常规血培养、心脏超声等检查仍无法明确诊断及分型,其中8例疑似感染性心内膜炎(IE),2例疑似囊袋感染。进而接受PET-CT检查。结果表明,经PET-CT检查后发现,3例患者不存在局部及系统感染,1例疑似IE患者为菌血症,另1例超声见可疑团块的疑似IE患者为电极拔除术后残留组织。结果表明,在本研究中的10例疑似诊断患者中,经PET-CT诊断确诊处理后,随访一年,10例均未出现新增感染及感染复发。结论在常规临床检查无法确诊的疑似CIED感染患者中,PET-CT可作为确定诊断方法。 Objective This study evaluated the usefulness of fluorodesoxyglucose marked by fluorine-18 (18F-FDG) positron emission tomography (PET) and computed tomography (CT) in patients with suspected cardiovascular implantable electronic device (CIED) infection. Methods From Jan 2013 to Jun 2014, patients treated for CIED infection in our center were enrolled. The patients, suspected as CIED infection without confirm evidence from symptom, blood culture, echocardiography, underwent 18F-FDG PET/CT. Post 1 year follow up, analysis the accuracy of diagnosis depended on18F-FDG PET/CT. Result From Jan 2013 to Jun 2014, there were 227 patients treated for CIED infection in our cen- ter. 10 of 227 cases was suspected as CIED infection without confirm evidence from symptom, blood culture, echocardio- graphy. Eight were suspected as infective endocarditis (IE), 2 as pocket infection. The results of 18F-FDG PET/CT sug- gested no infection in 2 patients with suspected pocket infection, 1 with suspected IE. One patient with suspected IE was diagnosed as bacteremia. 1 patient with vegetation, suspected IE, was diagnosed as no infection. All of the cases received standard treatment based on 18F-FDG PET/CT. Post follow up of 1 year, there were no recurrence and new infection ca- ses. Conclusions PET/CT is useful in diagnosis of CIED infection and classification.
出处 《中国心脏起搏与心电生理杂志》 2015年第5期449-453,共5页 Chinese Journal of Cardiac Pacing and Electrophysiology
基金 科技部国家科技支撑计划(项目编号:2014BAI11B08)
关键词 心血管病学 植入式心血管电子装置 感染 正电子发射型断层扫描 诊断 Cardiology Cardiovascular implantable electronic device Infection Positron emission tomography/com- puted tomography Diagnosis
  • 相关文献

参考文献11

  • 1陈进,李学斌,王龙,李鼎,张萍,段江波,苑翠珍,郭继鸿.经静脉途径拔除起搏电极导线的影响因素[J].中国心脏起搏与心电生理杂志,2012,26(6):489-491. 被引量:12
  • 2Wilkoff BL, Love CJ, Byrd CL, et al. Transvenous lead extraction: Heart Rhythm Society expert consensus on facilities, training, indications ,and patient management : this document was endorsed by the American Heart Association (AHA) [ J]. Heart Rhythm,2009,6 (7): 1 085. 被引量:1
  • 3Sandoe JA,Barlow G,Chambers JB,et al. Guidelines for the diagnosis ,prevention and management of implantable cardiac electronic device infection. Report of a joint Working Party project on behalf of the British Society for Antimicrobial Chemotherapy (BSAC,host organization ),British Heart Rhythm Society ( BHRS),British Cardiovascular Society ( BCS),British Heart Valve Society ( BHVS) and British Society for Echocardiography (BSE) [ J]. J Antimicrob Che-mother, 2015,70 (2) :325. 被引量:1
  • 4心律植入装置感染与处理的中国专家共识2013[J].临床心电学杂志,2013,22(4):241-253. 被引量:81
  • 5Deckx S, Marynissen T, Rega F, et al. Predictors of 30-day and 1-year mortality after transvenous lead extraction : a single-centre expe* rience[ J]. Europace,2014,16(8) :1 218. 被引量:1
  • 6Di Monaco A, Pelargonio G, Narducci ML, et al. Safety of trans-venous lead extraction according to centre volume ; a systematic review and meta-analysis[ J]. Europace, 2014,16(10) :1 496. 被引量:1
  • 7Baddour LM,Epstein AE,Erickson CC,et al. American Heart Association Rheumatic Fever, Endocarditis, and Kawasaki Disease Committee; Council on Cardiovascular Disease in Young; Council on Cardiovascular Surgery and Anesthesia ; Council on Cardiovascular Nursing ; Council on Clinical Cardiology ; Interdisciplinary Council on Quality of Care; American Heart Association. Update on car-diovascular implantable electronic device infections and their management :a scientific statement from the American Heart Association [J ]. Circulation, 2010,121:458. 被引量:1
  • 8Bensimhon L, Lavergne T, Hugonnet F, et al. Whole body [(18) F] fluorodeoxyglucose positron emission tomography imaging for the diagnosis of pacemaker or implantable cardioverter defibrillator infection :a preliminary prospective study [ J ]. Clin Microbiol Infect, 2011,17: 836. 被引量:1
  • 9Sarrazin JF, Philippon F, Tessier M, et al. Usefulness of fluorine-18 positron emission tomography/computed tomography for identification of cardiovascular implantable electronic device infections[ J]. J Am Coll Cardiol,2012,59:1 616. 被引量:1
  • 10Turpin S, Lambert R, Poirier N. An unusual looking pacemaker infection imaged with 18F-FDG PET/CT [ J ]. Eur J Nucl Med Mol Imaging, 2010,37 : 1 438. 被引量:1

二级参考文献18

  • 1Larry MB, Andrew EE, Christopher CE, et al. Update on cardiovascu- lar implantable electronic device infections and their management:a scientific statement from the American Heart Association [ J ]. Circu- lation,2010,121:458. 被引量:1
  • 2Margey R. Cardiac implantable electronic device infections:the ene- my that lurks beneath the skin[ J]. J Long Term Eft Med Implants, 2010,20 (3) :203. 被引量:1
  • 3Diemberger I, Biffi M, Martignani C, et al. From lead management to implanted patient management:indications to lead extraction in pace- maker and cardioverter- defibrillator systems [ J ]. Expert Rev Med Devices,2011,8(2) :235. 被引量:1
  • 4Moak JP, Mercader MA, Berul CI. Acute complications of electro- physiology and pacing procedures: identification and management [ J ]. Minerva Cardioangio1,2010,58 (4) :485. 被引量:1
  • 5Calvagna GM, Evola R, Valsecchi S. A complication of pacemaker lead extraction: pulmonary embolization of an electrode fragment [ J]. Europace,2010,12(5 ) :613. 被引量:1
  • 6郭继鸿,王斌主编.人工心脏起搏技术[M].第1版.北京:辽宁科学技术出版社,2008.104-115. 被引量:1
  • 7Farooqi FM, Talsania S, Hamid S, et al. Extraction of cardiac rhythm devices: indications, techniques and outcomes for the removal of pacemaker and defibrillator leads [ J ]. Int J Clin Pract, 2010,64 (8) :1 140. 被引量:1
  • 8Henrikson CA,Brinker JA. How to prevent, recognize, and manage complications of lead extraction. Part I : avoiding lead extraction-in- fectious issues [ J ]. Heart Rhythm,2008, 5 (7) : 1 083. 被引量:1
  • 9Love C J, Wilkoff BL, Byrd CL et al. Recommendations for extraction of chronically implanted transvenous pacing and defibrillator leads: indications, facilities, training. North American Society of Pacing and Electrophysiology Lead Extraction Conference Faculty. Pacing Clin Electrophysiol, 2000;23:544. 被引量:1
  • 10Darouiche RO. Trealment of infections ass iated with surgical implants. N Engl J Med, 2004;350:1422. 被引量:1