期刊文献+

油浸式变压器消防安全问题探讨 被引量:6

Discussion on Fire Safety Problems of Oil- immersed Transformers
下载PDF
导出
摘要 分析油浸式变压器火灾特点及原因,从气体继电器、压力释放阀等火灾预防技术,感温探测器、感烟探测器等火灾探测技术,固定水喷雾灭火、细水雾、排油注氮和"SP"速灭合成型低泡喷淋等灭火系统三大方面对油浸式变压器的消防安全问题进行探讨。 Fire features and fire reasons of oilimmersed transformers are analyzed, and the fire safety problems of oil-immersed transformers are studied from three main aspects, i. e. fire prevention technologies such as gas relays and pressure relief valves, fire detection technologies such as heat detectors and smoke detectors, and firefighting systems such as stationary water-spray fire extinguishing system, water-mist fire extinguishing system, oildrainage nitrogen-filling fire extinguishing system and SP synthetic foam-spray fire extinguishing.
作者 翟毅
出处 《建筑电气》 2015年第10期27-29,共3页 Building Electricity
关键词 油浸式变压器 火灾特点 火灾原因 火灾预防 火灾探测 水喷雾 细水雾 排油注氮 oil-immersed transformer fire features fire reasons fire prevention fire detection water-spray water-mist oil-drainage & nitrogen-filling
  • 相关文献

参考文献11

二级参考文献13

  • 1王清.500kV变电所变压器灭火系统[J].湖北电力,2004,28(B09):18-21. 被引量:5
  • 2任旭.油浸式电力变压器的火灾预防[J].消防技术与产品信息,2005,18(12):31-32. 被引量:2
  • 3公安部天津消防研究所.GB50016-2006建筑设计防火规范[S].北京:中国计划出版社,2006. 被引量:72
  • 4保定天威保变电气股份有限公司.电力变压器手册[M].北京:机械工业出版社,2003.. 被引量:20
  • 5GBJ16-1987,建筑设汁防火规范[S]. 被引量:1
  • 6GB50059-1992,35-110kV变电所设计规范[S]. 被引量:6
  • 7中国电力工程顾问集团东北电力设计院.GB50229-2006火力发电厂与变电站设计防火规范[S].北京:中国计划出版社.2006. 被引量:2
  • 8郭铁男.中国消防手册[M].第六卷.上海:上海科学技术出版社,2007:309-318. 被引量:1
  • 9公安部沈阳消防科学研究所.GB50116-2013火灾自动报警系统设计规范[S].北京:中国计划出版社,2013. 被引量:1
  • 10公安部沈阳消防科学研究所.GB50166-2007火灾自动报警系统施工及验收规范[S].北京:中国计划出版社,2007. 被引量:1