摘要
采用纳滤(NF)+反渗透(RO)工艺对北京某垃圾焚烧厂渗滤液进行深度处理。运行结果表明,NF/RO系统对COD、NH_3-N和电导率的去除率分别为94.2%、89.2%和65.0%,出水水质达到了《城市污水再生利用工业用水水质》(GB/T 19923—2005)中规定的敞开式循环冷却水系统补充水水质标准,运行费用合理,运行效果稳定。
The NF and RO process was used for advanced treatment of the landfill leachate from a waste incineration plant in Beijing. The operation results showed that the removal rates of COD, NH3 - N and conductivity were 94.2%, 89.2% and 65.0%, respectively. The effluent quality could meet the make-up water requirements for open recirculating cooling water system specified in the Reuse of Urban Recycling Water-Water Quality Standard for Industrial Uses (GB/T 19923 -2005 ). The NF and RO process had the reasonable operation cost and stable operation effect.