期刊文献+

动态干涉仪的位相光栅衍射效率研究 被引量:3

Diffraction efficiencies of phase gratings based on dynamic interferometer
下载PDF
导出
摘要 为了解决普通二维光栅在动态干涉术中光能量利用不足的问题,使用标量衍射理论和傅里叶分析法对矩形正交位相光栅和棋盘型位相光栅的衍射效率进行推导,分别对两种光栅的最佳工作级次选择策略进行研究。分析结果表明,当分光器件为矩形正交位相光栅时,应选择(0,±1)级与(±1,0)级作为动态干涉仪的工作级次,光能量利用率达到54.4%;当分光器件为棋盘位相光栅时,应选择(±1,±1)级作为动态干涉仪的工作级次,光能量利用率达到65%。实验对比了两种光栅在动态干涉仪上的应用效果,当选用(±1,±1)级作为工作级次时,结果表明使用棋盘型位相光栅的应用效果优于矩形正交位相光栅。因此在动态干涉仪中使用棋盘位相光栅并选用(±1,±1)级作为工作级次能够消除光能量利用不足对测量造成的影响。 In order to overcome the insufficient of the light energy diffracted by common two dimension grating in dynamic interferometry, diffraction efficiency of the cross phase grating and phase chessboard were derived using scalar analysis and Fourier method, and selection scheme of optimum operation orders was studied. The analytical result of their diffraction efficiency demonstrates that if the cross phase grating is chosen, the(0,±1)th and(±1,0)th orders should be selected as operation orders, and utilization rate can reach 54.4%; If the phase chessboard is chosen, (±1,±1)th orders is selected as operation ones, and utilization rate can reach 65%. Application effect of these two phase grating are compared in dynamic interferometer. When (±1,±1)th is selected as operation orders, the experimental results indicates that application effect of phase chessboard is better than that of cross phase grating. So influence of insufficient light energy on the measurement result can be eliminated by using phase chessboard and selecting (±1,±1)th as operation orders.
出处 《红外与激光工程》 EI CSCD 北大核心 2015年第9期2696-2701,共6页 Infrared and Laser Engineering
基金 国家自然科学基金(61108041 U1231111)
关键词 光学干涉测量 动态干涉仪 位相光栅 衍射效率 optical interferometry dynamic interferometer phase grating diffraction efficiency
  • 相关文献

参考文献15

  • 1云宇,解平,彭勇,陈兴无,徐熙平.基于Talbot效应检测光束准直性方法的研究[J].红外与激光工程,2008,37(S1):267-269. 被引量:5
  • 2陆衡,陈好,何勇,李建欣,胡绍云,张浩,孟庆安.基于泰伯莫尔法的长焦距测量系统的装调技术[J].红外与激光工程,2013,42(10):2836-2841. 被引量:4
  • 3Zhiqiang Liu, Masashi Okada, Katsumi Sugisaki, et al.Double-grating lateral shearing interferometer for EUV optics at-wavelength measurement[C]//SPIE, 2005, 5752: 663-672. 被引量:1
  • 4Yucong Zhu, Satom Odate, Ayako Sugaya, et al. Method for designing phase-calculation algorithms for two-dimensional grating phase-shifting intefferometry [J]. Appl Opt, 2011, 50 (18): 2815-2822. 被引量:1
  • 5左芬,陈磊.一种同步移相干涉测量系统的误差研究[J].光学技术,2009,35(4):536-540. 被引量:4
  • 6Li Bo, Chen Lei, Zhao Bing, et al. Spatial mismatch calibration using circular carder technique in the simultaneous phase shifting interferometry[J]. Appl Opt, 2012, 51 (8): 1037-10. 被引量:1
  • 7Qian Kemao, Wu Xiaoping, Anand Asundi. Grating-based real-time polarization phase-shifting interferometry: error analysis[J]. Appl Opt, 2002, 41(13): 2448-2453. 被引量:1
  • 8Neal Brock, John Hayes, Brad Kimbrough, et al. Dynamic Interferometry[C]//SPIE, 2005, 5875, 1-10. 被引量:1
  • 9Kevin G H, Steven L C. Phase grating use in moire interferometry[J]. Appl Opt, 1984, 23(10):1517-1520. 被引量:1
  • 10Vanusch Nercissian, Irina Harder, Klaus Mantel, et al. Diffractive simultaneous bidirectional sheafing interferometry using tailored spatially coherent light[J]. Appl Opt, 2011, 50 (4): 571-578. 被引量:1

二级参考文献17

  • 1云宇,解平,彭勇,陈兴无,徐熙平.基于Talbot效应检测光束准直性方法的研究[J].红外与激光工程,2008,37(S1):267-269. 被引量:5
  • 2吴栋,朱日宏,陈磊,王青,何勇,高志山.抗振型移相干涉测量术的进展[J].光学仪器,2004,26(5):59-64. 被引量:5
  • 3左芬,陈磊,徐春生.基于二维光栅分光的同步移相干涉测量技术[J].光学学报,2007,27(4):663-667. 被引量:20
  • 4James C Wyant. Advances in interferometric metrology[J ]. Proc SPIE, 2002,4927 : 154-162. 被引量:1
  • 5J E Millerd, N J Brock. Methods and Apparatus for Splitting, Imaging and Measuring wave fronts in interferometry [ P ]. U S Patent: 6 304 330, 2001. 被引量:1
  • 6Jungjae Park, HagyongKihm, Seung Woo Kim. Point-diffraction Fiber Interferometer for Vibration Desensitization [J ]. Proc SPIE, 2005, 5856: 922-929. 被引量:1
  • 7James C Wyant. Vibration Insensitive Interferometric Optical Testing [A]. Optical Society of America[C]. 2004. 被引量:1
  • 8J E Millerd, NJ Brock, J Hayes, et al. Pixelated Phase-Mask Dynamic Interferometer[J]. Proc SPIE, 2004,5531 : 304-314. 被引量:1
  • 9A Hettwer, J Kranz, J Schwider. Three channel phase-shifting interferometer using polarization-optics and a diffraction grating [J ]. Opt Eng, 2000, 39(4): 960-966. 被引量:1
  • 10Jin Xiongrong, Zhang Jinchun, Bai Jian. Calibration method for high-accuracy measurement of long focal length with Talbot interferometry [J]. Appied Optics, 2012, 51 (13): 2407-2413. 被引量:1

共引文献10