本文结合建筑工程质量鉴定与施工图审查的实践,对湿式闭式自动喷水灭火系统水泵扬程的计算、倒流防止器的合理使用以及生活消防水池分设抑或合用的问题进行了探讨。
Combining the practices of construction engineering quality appraisal and construction drawing audit,the paper discusses the calculation of pump head for the wet-type closed automatic sprinkler system,reasonable use of anti-backflow device,as well as separate or combined design of domestic water pool and fire pool.
出处
《建筑科学》
CSCD
北大核心
2015年第6期163-167,共5页
Building Science
关键词
湿式闭式自动喷水灭火系统
倒流防止器
生活消防水池
wet-type closed automatic sprinkler system
anti-backflow device
domestic water pool / fire pool