期刊文献+

Liquid chromatography-tandem mass spectrometry method for the estimation of adefovir in human plasma:Application to a pharmacokinetic study

Liquid chromatography-tandem mass spectrometry method for the estimation of adefovir in human plasma:Application to a pharmacokinetic study
下载PDF
导出
摘要 An analytical method based on solid phase extraction was developed and validated for analysis of adefovir in human plasma. Adefovir-d4 was used as an internal standard and Synergi MAX RP80A (150rnmx4.6mm. 41am) column provided the desired chromatographic separation of compounds followed by detection with mass spectrometry. The method used simple isocratic chromato- graphic condition and mass spectrometric detection in the positive ionization mode. The calibration cuives were linear over the range of 0.50-42.47 ng/mL with the lower limit of quantitation validated at 0.50 ng/mL. Matrix effect was assessed by post-column infusion experiment to monitor phospholipids and post- extraction addition experiment was performed. The degree of matrix effect for adefovir was determined as 7.5% and ion-enhancement in five different lots of human plasma was 7.1% and had no impact on study samples analysis with 4.5 rain run time. The intra- and inter-day precision values were within 7.7% and 7.8%, respectively, for adefovir at the lower limit of quantification level. Validated bioanalytical method was successfully applied to clinical sample analysis. An analytical method based on solid phase extraction was developed and validated for analysis of adefovir in human plasma. Adefovir-d4 was used as an internal standard and Synergi MAX RP80A (150rnmx4.6mm. 41am) column provided the desired chromatographic separation of compounds followed by detection with mass spectrometry. The method used simple isocratic chromato- graphic condition and mass spectrometric detection in the positive ionization mode. The calibration cuives were linear over the range of 0.50-42.47 ng/mL with the lower limit of quantitation validated at 0.50 ng/mL. Matrix effect was assessed by post-column infusion experiment to monitor phospholipids and post- extraction addition experiment was performed. The degree of matrix effect for adefovir was determined as 7.5% and ion-enhancement in five different lots of human plasma was 7.1% and had no impact on study samples analysis with 4.5 rain run time. The intra- and inter-day precision values were within 7.7% and 7.8%, respectively, for adefovir at the lower limit of quantification level. Validated bioanalytical method was successfully applied to clinical sample analysis.
出处 《Journal of Pharmaceutical Analysis》 SCIE CAS 2015年第3期190-199,共10页 药物分析学报(英文版)
基金 support and facilities received from Ranbaxy Research Laboratories Gurgaon,India
关键词 Liquid chromatography-tandem massspectrometry Solid phase extraction Pharmacokinetic study Liquid chromatography-tandem massspectrometry Solid phase extraction Pharmacokinetic study
  • 相关文献

参考文献15

  • 1K.c. Cundy, Clinical pharmacokinetics of the antiviral nucleotide analogues cidofovir and adefovir, Clin. Phannacokinet 36 (1999) 127-143. 被引量:1
  • 2R.B Qaqish, K.A. Mattes, OJ. Ritchie, A new antiviral agent for the treatment of hepatitis B virus infection, Clin.Ther. 25 (2003) 3084-3099. 被引量:1
  • 3B.P Kearney, S Ramanathan, A.K Cheng, et al., Systemic and renal pharmacokinetics of adefovir and tenofovir upon coadministration, J. Clin. Phannacol. 45 (2005) 935-940. 被引量:1
  • 4S. Lecompte, M. Furtado, A. Hardy, et al., Quantitative determination of adefovir in human plasma using LClMSIMS, APPS 001 (2004) 608. 被引量:1
  • 5H.c. Bi, G.P. Zhong, S. Zhou, et al., Determination of adefovir in human plasma by liquid chromatography/tandem mass spectrometry: application to a phannacokinetic study, Rapid. Commun. Mass Spectrom. 19 (2005) 2911-2917. 被引量:1
  • 6H.T. Xie, G.J. Wang, M.J. Xu, et al., A new LC-MS-MS method for quantitative analysis of adefovir, and its use for phannacokinetic studies in healthy Chinese volunteers, Chromatographia 71 (2010) 587-593. 被引量:1
  • 7D Sun, HWang, B Wang, et al., Development and validation of a sensitive LC-MSIMS method for the determination of adefovir in human serum and urine, J. Phann. Biomed. Anal. 42 (2006) 372-378. 被引量:1
  • 8J.E Vela, L.Y Olson, A. Huang, et al., Simultaneous quantitation of the nucleotide analog adefovir, its phosphorylated anabolites and 2'deoxyadenosine triphosphate by ion-pairing LCIMSIMS, J. Chromatogr. B Analyt. Techno!. Biomed. Life Sci. 848 (2007) 335-343. 被引量:1
  • 9Z. Xiong, Y. Zhang, F. Qin, et al., Hydrophilic interaction liquid chromatography-tandem mass spectrometry for the determination of adefovir in human plasma and its application to a phannacokinetic study, J. Chromatogr. B Analyt. Techno!' Biomed. Life Sci. 878 (2010) 2111-2116. 被引量:1
  • 10X. Chen, D. Liu, L. Zhu, et al., Development and validation of a liquid chromatography/tandem mass spectrometry procedure for the quantification of adefovir in human plasma, Rapid. Commun. Mass Spectrom. 19 (2005) 1893-1898. 被引量:1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部