摘要
本文简述了S Zorb装置自开工运行以来发生的较为重要的异常状况,其中包括闭锁料斗过滤器ME102泄漏、再生器取热盘管的泄露和再生器下料中断三项,并对原因进行了简要的分析,提出了进一步的解决方案。
This paper briefly described important abnormal situations in S Zorb unit Since started operation. Including ME-102 of lockhooper leak, Regenerator hot coil pipe leak and Adsorbent transmission in Regenerator bottom interrupt. The reasons why things happen were analyzed, and put forward the solution to solve these problems
出处
《广东化工》
CAS
2015年第11期205-206,共2页
Guangdong Chemical Industry