期刊文献+

铁塔公司室分合路建设干扰问题的分析和对策 被引量:1

Analysis and Countermeasure of Interference Problem in the Construction of the Tower Company Room
下载PDF
导出
摘要 目前铁塔公司为满足三家运营商多频段接入的室分建设方案处于探索阶段,多频段、多路天馈的干扰问题没有进行全面的理论分析和实践测试,如果盲目建设,将导致巨大的人力物力资源浪费。台州三大运营商室分系统存在9个室分频段、单路和双路天馈的应用场景,但是却没有4个以上合路的应用场景。通过理论分析和实践测试,获得适合不同场景的通用室分解决方案,为后续的室分建设提供了十分重要的参考价值。对类似的宏站合路建设中,也提供了重要的分析思路和参考价值。 The tower company to meet the three operators multi band access room construction scheme in the stage of exploration, multi band, multi antenna interference no comprehensive theoretical analysis and practical tests, if the blind construction will lead to enormous human and material resources waste. Taizhou three operators room system has nine rooms frequency, single channel and dual antenna application scenarios, but no more than four combination application scenarios. Through theoretical analysis and practical test, it is suitable for the general room solution of different scenes, which provides a very important reference value for the follow-up of the room construction. It also provides important analysis ideas and reference value for the construction of similar macro station path.
出处 《无线互联科技》 2015年第8期92-95,共4页 Wireless Internet Technology
关键词 室分建设 POI设备 干扰分析 合路测试 铁塔公司 Room construction POI equipment Interference analysis Road test Iron tower company