摘要
目的:建立高效液相色谱法测定慢性盆腔炎丸中阿魏酸的含量测定方法。方法用 C18柱为固定相,以乙腈-0.085%磷酸溶液(14:86)为流动相,检测波长为316 nm。结果阿魏酸进样量在0.02049~0.2049μg范围内呈良好的线性关系,r=1.000(n=7),其平均回收率(n=6)为100.10%。方法的检测限0.3073 ng,定量限1.0243 ng。结论此法可靠、准确、专属性强。
Objective To establish an HPLC method for the determination of ferulic acid in Chronic Pelvic Inflammation Pills.Methods The C18 column was used with the mixture of acetonitrile-0.085 % phosphoric acid (14:86) as the mobile phase, and the detection wavelength was 316 nm.Results The standard curve of ferulic acid was linear in the range of 0.02049-0.2049μg (r=1.000,n=7), and the average recovery was 100.10 % (n=6). The limit of detection was 0.3073 ng and the limit of quantification was 1.0243 ng.Conclusion The method can be reliable, accurate and specific.
出处
《食品与药品》
CAS
2015年第3期201-203,共3页
Food and Drug
关键词
慢性盆腔炎丸
阿魏酸
Chronic Pelvic Inflammation Pills
ferulic acid