期刊文献+

Monte Carlo Simulation of in situ Gamma-Spectra Recorded by Na I(Tl) Detector in the Marine Environment 被引量:4

Monte Carlo Simulation of in situ Gamma-Spectra Recorded by Na I(Tl) Detector in the Marine Environment
下载PDF
导出
摘要 To develop a NaI (T1) detector for in situ radioactivity monitoring in the marine environment and enhance the confidence of the probability of the gamma-spectrum analysis, Monte Carlo simulations using the Monte Carlo N-Particle ( MNCP ) code were performed to provide the response spectra of some interested radionuclides and the background spectra originating from the natural radionuclides in seawater recorded by a NaI (T1) detector. A newly developed 75 mm × 75 mm NaI (T1) detector was calibrated using four reference radioactive sources 137Cs, 60Co, 40K and 54Mn in the laboratory before the field measurements in seawater. A simulation model was established for the detector immersed in seawater. The simulated spectra were all broadened with Gaussian pulses to reflect the statistical fluctuations and electrical noise in the real measurement. The simulated spectra show that the single-energy photons into the detector are mostly scattering low-energy photons and the high background in the low energy region mainly originates from the Compton effect of the high energy y-rays of natural radionuclides in seawater. The simulated background spectrum was compared with the experimental one recorded in field measurement and they seem to be in good agreement. The simulation method and spectra can be used for the accurate analysis of the filed measurement results of low concentration radioactivity in seawater. To develop a Na I(Tl) detector for in situ radioactivity monitoring in the marine environment and enhance the confidence of the probability of the gamma-spectrum analysis, Monte Carlo simulations using the Monte Carlo N-Particle( MNCP) code were performed to provide the response spectra of some interested radionuclides and the background spectra originating from the natural radionuclides in seawater recorded by a Na I(Tl) detector. A newly developed 75 mm × 75 mm Na I(Tl) detector was calibrated using four reference radioactive sources 137 Cs, 60 Co, 40 K and 54 Mn in the laboratory before the field measurements in seawater. A simulation model was established for the detector immersed in seawater. The simulated spectra were all broadened with Gaussian pulses to reflect the statistical fluctuations and electrical noise in the real measurement. The simulated spectra show that the single-energy photons into the detector are mostly scattering low-energy photons and the high background in the low energy region mainly originates from the Compton effect of the high energy γ-rays of natural radionuclides in seawater. The simulated background spectrum was compared with the experimental one recorded in field measurement and they seem to be in good agreement. The simulation method and spectra can be used for the accurate analysis of the filed measurement results of low concentration radioactivity in seawater.
出处 《Journal of Ocean University of China》 SCIE CAS 2015年第3期471-474,共4页 中国海洋大学学报(英文版)
基金 financial support from the International Science & Technology Cooperation Program of China (No. 2013DFR90220) National Natural Science Foundation of China (No. 41206076) Qingdao Applied Basic Research Project (NO. 14-2-4-94-jch)
关键词 Monte Carlo simulation marine radioactivity monitoring NaI (T1) detector response spectra background spectra 蒙特卡罗模拟 海洋环境 探测器 碘化钠 伽玛 天然放射性核素 放射性监测 录制
  • 相关文献

参考文献2

二级参考文献18

  • 1国家环境保护总局.HJ/T 61-2001,辐射环境监测技术规范[S].北京:中国标准出版社,2001. 被引量:1
  • 2P.P.Povinec,L Osvath,M.S.Baxter.Underwater Gamma-spectrometry with HPGe and NaI(T1) Detectors[J].Applied Radiation and Isotopes,1996,47(10):1127-1133. 被引量:1
  • 3C.Tsabaris,D.Ballas.On line gamma-ray spectrometry at open sea[J].Applied Radiation and Isotopes,2005,62(1):83-89. 被引量:1
  • 4C.Tsabaris,C.Bagatelas,Th.Dakladas,et al.An autonomous in situ detection system for radioactiviw measurements in the marine environment[J].Applied Radiation and Isotopes,2008,66 (10):1419-1426. 被引量:1
  • 5Ch.Wedekind,G.Schilling,M.Gruttmuller,et al.Gamma-radiation monitoring network at sea[J].Applied Radiation and Isotopes,1999,50(4):733-741. 被引量:1
  • 6D.S.Bale and C.Szeles.Design of High Performance CdZnTe Quasi-Hemispherical Gamma-ray CAPtureTM Plus Detectors[J].Proceedings of SPIE,2006,6319. 被引量:1
  • 7Thomas H.Prettyman,Morag K.Smith,and Steven E.Soldner.Design and Characterization of Cylindrical CdZnTe Detectors with Coplanar Grids[J].Proceedings of SPIE,1999,3768.pp.339-347. 被引量:1
  • 8R.Vlastou,I.TH.Ntziou,M.Kokkoris,et al.Monte Carlo simulation of γ-ray spectra from natural radionuclides recorded by a NaI detector in the marine environment[J].Applied Radiation and Isotopes,2006,64(1):116-123. 被引量:1
  • 9ASHRAFI S,ANVARIAN S,SOBHANIAN S. Monte Carlo modeling of a NaI(Tl)scintillator[J].Journal of Radioanalyt-ical and Nuclear Chemistry,2006,(01):9598. 被引量:1
  • 10BRIESMEISTER J F. MCNP-A general Monte Carlo N-par-ticle transport code Version-4C.LA-13709-M[R].Los Ala-mos,. 被引量:1

共引文献19

同被引文献15

引证文献4

二级引证文献6

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部