分析了水布垭电站导叶套筒漏水的原因,提出了几种可行的改进方法,对比分析各改进方法的优劣,寻找解决水布垭电站导叶套筒漏水处理的最佳方法。
The Leakage fault of guide vane sleeve is found in hydro-turbines in Shuibuya Hydropower Station. Reasons of this fault are analyzed. Several feasible treatment measures are then proposed and compared. The most preferable scheme is suggested.