期刊文献+

酶联免疫法测定水产品中氯霉素残留 被引量:6

The Determination of Chloramphenicol Residues in Aquatic Products by the ELISA
原文传递
导出
摘要 为保证水产品的质量安全,采用酶联免疫法(ELISA)测定鱼、虾水产品中氯霉素含量。试验结果表明,氯霉素标准半对数曲线为Y=-48.321X+5.564 9,R2=0.999 7,方法精密度为1.28%,检出限为6.25 ng/kg,加样回收率为83.67%~87.06%,所检测的50份水产品中,绝大多数样品在饲喂过程中未使用氯霉素,检测结果符合我国相关限量标准。 In order to investigate the quality and security of aquatic products,the residues of chloramphenicol in aquatic product samples was detected using enzyme linked immunosorbant assay(ELISA).The results indicated that the standard curve for chloramphenieol was Y=-48.321X+5.564 9,R^2=0.999 7,the recoveries was 83.67%~87.06%,the majority of the selected samples were not deeded chloramphenieol,the results was within the limit developed by our government.
出处 《食品工业》 北大核心 2015年第6期273-275,共3页 The Food Industry
基金 2014年农产品质量安全风险评估应急处置财政专项
关键词 酶联免疫(ELISA) 水产品 氯霉素 enzyme linked immunosorbant assay (ELISA) aquatic products chloramphenieol
  • 相关文献

参考文献6

二级参考文献36

共引文献62

同被引文献104

引证文献6

二级引证文献39