池火灾是可燃液体储罐区易发生的主要火灾类型。本文总结了mudan池火灾计算模型,结合人员、设备等的热辐射受损模型和多米诺二次事故概率模型,模拟了有风情况下池火灾的事故后果,分别得到了上风向和下风向池火灾热通量关系图,伤害/破坏半径以及多米诺二次事故频率。
The pool fire is a major type in flammable liquid storage tank zone. The model of mudan was summarized, combined with thermal radiation damage models such as personnel, equipment and domino secondary accident probability model, and then simulated pool fire accident consequences under the conditions of wind. The drawings about thermal radiation, the harm/damage radius and domino secondary accident frequency were gotten, which were about upwind and down the wind respectively.