期刊文献+

激光多普勒测速中平板窗口对测量体位置及形态的影响 被引量:2

Effect of Measurement Volume Shift and Fringe Distortion Due to Beam Refractions through the Plane Window for LDA Applications
下载PDF
导出
摘要 应用激光多普勒测速仪(Laser Doppler anemometer,LDA)进行内流场测试时,激光光束光轴垂直和倾斜经过平板窗口后,由于折射效应导致LDA系统测量体位置和形态发生改变,进而影响所测速度大小和方向。为了研究折射效应对测量体位置和速度方向的影响,建立激光光路经平板窗口折射的数学模型,应用此模型进行不同工况(光束入射角θ、光束半夹角α1、内流场介质折射率n3、平板厚度d和LDA探头位置)下的理论研究;为了研究折射效应对测量体形态(即条纹畸变)的影响,建立LDA标定试验系统,进行不同光束入射角试验研究。研究结果表明,控制θ在10°以内可以忽略其折射效应影响;α1对于测量体位置偏差影响较小,但对于速度偏角有一定的影响,并且α1在5°以内时可以忽略其影响;使壁面两侧折射率尽可能的接近,会减小折射效应;沿测量体长度方向,折射后的测量体条纹间距线性增加,并随着θ的增加,条纹间距趋于均匀化。 Using laser Doppler anemometer(LDA) to measure velocities in inner flow field, due to the refraction after the laser beams through the flat window vertically or aslant, the measuring volume position and shape change, and affect the measured velocity. For studying the refraction effect on measuring volume shift and velocity direction, a mathematical model of the laser beams through the flat window refraction was established, using this model to study the refraction effect under the different working conditions(the beams incident angleθ, the beams half angleα1, the refractive index of the flow n3, plane thickness d and LDA probe location);for studying the refraction effect on measurement of fringe distortion under differentθ, the LDA calibration test system was established. Results show that the refraction effect can be ignored within 10° ofθ, 5° ofα1.The refractive index of both the plane sides as close as possible, will reduce the refraction effect; Along the length of the measurement volume direction after refraction, fringe spacing increases linearly, and with the increase ofθ, fringe spacing tend to be uniform.
出处 《机械工程学报》 EI CAS CSCD 北大核心 2015年第8期198-203,共6页 Journal of Mechanical Engineering
基金 国家自然科学基金青年科学基金(50905016) 部级预研(40402060103)资助项目
关键词 激光多普勒测速 折射效应 测量体偏移 条纹畸变 速度修正 标定装置 laser Doppler anemometer beam refraction measurement volume shift fringe distortion velocity bias calibration facility
  • 相关文献

参考文献14

二级参考文献18

  • 1Zhang Z,Experiments in Fluids,1995年,19卷,89页 被引量:1
  • 2朱德忠,热物理激光测试技术,1990年 被引量:1
  • 3Edwards R V,Dybbs A.Refractive index matching for velocity measurements in complex geometries [J].TSI Quarterly,1984,10(4):3~13. 被引量:1
  • 4Lowe K L,Kutt P H.Refraction through cylindrical tubes [J].Experiments in Fluids,1992,13:315~320. 被引量:1
  • 5Muguercia I,Largaespada E,Li W,et al.Fluid flow behavior inside a circular helicoidal pipe using a laser doppler anemometer/velocimetry (LDA/LDV) system [A].The 3rd World Conference on Experimental Heat Transfer,Fluid Mechanics and Thermodynamics,Honolulu,1993. 被引量:1
  • 6Budwig R.Refractive index matching method for liquid flow investigations [J].Experiments in Fluids,1994,17:350~355. 被引量:1
  • 7Parker J,Merati P.An investigation of turbulent Taylor-Couette flow using laser doppler velocimetry in a refractive index matched facility [J].ASME Journal of Fluids Engineering,1996,118(12):810~818. 被引量:1
  • 8Bertolotti C,Doplano V.Three-dimensional numerical simulation of flow through a stenosed coronary bypass [J].Journal of Biomechanics,2000,33:1 011~1 022. 被引量:1
  • 9Meyers J F. Laser Velocimetry: The Elusive third component,9th International Invitational Symposium on the Unification of Finite Elements, Finite Differenees and Caleulus of Variations,Worcester, Massachusetts, 1987. 被引量:1
  • 10DUALPDA Reference Guide, Dantec, 1997. 被引量:1

共引文献12

同被引文献34

  • 1徐劲祥.靶场外弹道试验弹丸速度测定研究[J].战术导弹控制技术,2006(2):89-92. 被引量:5
  • 2Gaster M, Maybrey J F M. An optical instrument for meas- uring fluctuating velocities in highly turbulent flows [J]. Aeronautical Quarterly, 1978,29(2) : 98-113. 被引量:1
  • 3ZHANG Xiao-ling, ZHANG Bao-feng, LIN Yu-chi. Accurate phase expansion on reference planes in grating projection profilometry[J]. Measurement Science and Technology, 2011,22(7) :075301. 被引量:1
  • 4ZHANG Xiao-ling, LUO Yin-sheng, LIN Yu-chi, et al. Re- search on robot navigation vision sensor based on grating projection stereo vision[A]. Proc. of Advanced Optical Manufacturing Technologies, OMT16 [C]. 2016, OM200- 36. 被引量:1
  • 5ZHANG Bao-feng, TIAN Xiu-zhen, ZHANG Xiao-ling. A camera calibration method based on plane grid points [J]. Advanced Materials Research,Frontiers of Manufac- turing Science and Measuring Technology, 2011, 230- 232:723-727. 被引量:1
  • 6Marko vaco, Bojan sekoranja, Filip Suligoj, et al. Cali- bration of an industrial robot using a stereo vision system [J]. Procedia Engineering, 2014,69 : 459-463. 被引量:1
  • 7LI Fu-bing, HE Qiong, HUANG Cheng-wu, et al. High frame rate and high line density ultrasound imaging for lo- cal pulse wave velocity estimation using motion matc- hing:A feasibility study on vessel phantoms[J]. Ultrason-ics,2016,67(4):41-54. 被引量:1
  • 8Wajahat Kazmi, Sergi Foix, Guillem Aleny., et al. Indoor and outdoor depth imaging of leaves with time-of-flight and stereo vision sensors: Analysis and comparison[J]. ISPRS Journal of Photogrammetry and Remote Sensing, 2014,88(1) :128-146. 被引量:1
  • 9ZHANG Bao-feng, LI dia-lu, ZHANG Xiao-ling. Application of SIFT algorithm in 3D scene reconstruction[J]. Ad- vanced Materials Research, Sustainable Development of Natural Resources,2012,616-618:1956-1960. 被引量:1
  • 10LI Yong-hong, CHEN Jia-bin, WANG Yong. The study on anti-high-g technology of missile body attitude measure- ment system[A]. Proc. of International Conference on Au- tomatic Control and Artificial Intelligence (ACAI 2012) [07. 2012,2195-2198. 被引量:1

引证文献2

二级引证文献9

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部