期刊文献+

96例极低出生体重儿PICC导管的应用 被引量:13

Application of PICC Catheter in 96 Cases of Very Low Birth Weight
下载PDF
导出
摘要 目的:总结极低出生体重儿应用外周置入中心静脉导管(PICC)的护理体会。方法:选用美国BD公司生产的1.9Fr型号PICC管对96例极低出生体重儿实施PICC置管回顾性总结置管时机、置管静脉与部位、导管的应用及并发症的发生情况和处理方法。结果:96例患儿一针穿刺成功率93.8置管长度为6.5~14.0cm置管时间7~62天不完全堵管14例导管相关性血流感染4例。结论:PICC穿刺时机宜选择在病情平稳肢体无水肿时穿刺部位应首选肘部的贵要静脉实际置管长度比体表测量长度值小0.5cm^1cm正确的维护能延长置管时间并减少并发症的发生。 Objective: To summarize the very low birth weight using peripheral experience from the nursing of central venous catheter (PICC) placement.Methods:Choose the BD company produces 1.9 Fr models PICC tube in 96 cases of very low birth weight implementation or+ PICC catheter were retrospectively summarized venous catheter time,catheter and parts,the application of the catheter and the occurrence of complications and treatment methods.Results:96 cases of children with a success rate of first puncture is 93.8 needle tube length is 6.5-14.0 cm catheter time is 7-62 days not completely blocking pipe is 14 cases catheter-related bloodstream infection is 4 cases.Conclusion:PlCC puncture made when choosing members in stable condition with no edema of puncture should be first choice of the elbow to venous catheter actual length is smaller than surface measuring length value 0.5-1cm correct maintenance can extend the time of catheter and reducing complications.
出处 《中国医药导刊》 2015年第4期418-420,共3页 Chinese Journal of Medicinal Guide
关键词 早产儿 极低出生体重儿 经外周静脉置入中心静脉导管术 Premature babies Very low birth weight Via peripheral vein in central venous catheter
  • 相关文献

参考文献10

二级参考文献23

  • 1姜红,明秀芬.低体重儿经外周静脉置入中心导管术后导管异位及漂移的分析[J].中国实用护理杂志(下旬版),2006,22(2):34-34. 被引量:15
  • 2欧阳一鸣 胡瑞祥.PICC在全胃肠外营养中的应用[J].云南医药,1999,20(1):27-28. 被引量:1
  • 3陈蕤.外周导入中心静脉置管及其护理[J].实用护理杂志,1997,13(8):409-410. 被引量:48
  • 4Infusion Nurses Sociely.Infusion nursing standards of practice[J].JInfus Nurs,2011,34(2):44-45. 被引量:1
  • 5张玉屏,张学明.胸部影像诊断及鉴别[M].北京:军事医学科学出版社,2012:12. 被引量:1
  • 6Harako ME,Nguyen TH,Cohen AJ,et al.Optimizing the pa- tient positioning for PICC line tip determination[J].Emerg Ra- diol,2004,10(4):I86-189. 被引量:1
  • 7Nowlen TT,Rosenthal GL,Johnson GL,et al.Pericardial effu- sion and tamponade in infants with central catheters[J].Pedia- trics,2002,(110):137-142. 被引量:1
  • 8Laurent T,Nathalie S,Corinne J,et al.Echocardiography allows more accurate placement of peripherally inserted central cathe- ters in low birthweight infants[J].Acta Paediatr,2013,102(1):703-706. 被引量:1
  • 9Forauer AR,Alonzo M.Change in peripherally inserted central catheter tip position with abduction and adduction of the upper extremity[J].J Vasc Interv Radiol,2000,11(10):1315-1318. 被引量:1
  • 10Nadroo AM,Glass RB,Lin J,et al.Changes in upper extremity osition cause migration of peripherally inserted central catheters in neonates[J].Pediatrics,2002,110(1 Pt 1):131-136. 被引量:1