期刊文献+

兆瓦级风力机组偏航齿圈螺栓联接强度分析 被引量:7

Strength analysis of bolt connection on yaw gear of MW wind turbine generator system
下载PDF
导出
摘要 建立兆瓦级风力发电机组偏航过程动力学模型和偏航齿圈与塔架法兰处螺栓联接三维模型并运用Hypermesh软件处理,在ABAQUS中建立螺栓接触模型,取预紧力为屈服极限σp0.2的60%~80%对螺栓联接偏航过程静力学性能进行分析。研究结果表明:通过对比不同预紧力工况下得出的应力强度与疲劳强度,提出可供参考的预紧力Fv取值范围;当且预紧力为0.7σp0.2时,螺栓及其连接件应力应变最理想,在仅受预紧力和加载极限载荷后最大应力分别为712.5 MPa和733.4 MPa,工作应力下的安全系数SF=1.28,满足强度设计要求,为该兆瓦级风力发电机组偏航齿圈螺栓联接及其他连接系统的应力强度校核、疲劳分析等提供参考,便于进一步优化设计。 In order to develop a kind of heat pipe exchanger used for exhaust energy recovery of air-conditioning system, one kind plate pulsating heat pipe was designed and experimentally investigated. The influence on heat transfer performance of cold and hot length ratio, working liquid, filling ratio and inclination angle was analyzed under the effect of forced air convection cooling conditions. The results show that the heat pipe has the best heat transfer performance when the ratio of cold length and hot length is 6:4, heat transfer performance is better when the working liquid is acetone rather than water, and the effect of inclination angle is very small. Heat pipe has the highest heat transfer performance and the lowest starting temperature when the working liquid is acetone and the filling ratio is 20%, which can be used to exhaust energy recovery of air-conditioning system.
出处 《中南大学学报(自然科学版)》 EI CAS CSCD 北大核心 2015年第1期310-316,共7页 Journal of Central South University:Science and Technology
基金 可再生能源电力技术湖南省重点实验室开放基金资助项目(2011KFJJ001)~~
关键词 螺栓联接 偏航齿圈 风力发电机 强度分析 bolt connection yaw gear wind turbine generator strength analysis
  • 相关文献

参考文献15

  • 1Chou J S, Tu C W. Failure analysis and risk management of a collapsed large wind turbine tower[J]. Engineering Failure Analysis, 2011,18(1): 295-313. 被引量:1
  • 22230 Part I, Systematic calculation of high duty bolted joints, joints with one cylindrical bolt[S]. 被引量:1
  • 3Naruse T, Shibutani Y. Equivalent stiffness evaluations of clamped plates in bolted joints under loadingjf]. Journal of Solid Mechanics and Materials Engineering, 2010, 4(12): 1791-1805. 被引量:1
  • 4HUANG Yonghui, WANG Ronghui. Finite element analysis and experimental study on high strength bolted friction grip connections in steel bridges[J]. Journal of Constructional Steel Research, 2010, 66(6): 803-815. 被引量:1
  • 5Lee S H, Kim J H, Choi S M. Structural behavior of tension joint with high-strength bolted split-tee[J]. International Journal of Steel Structures, 2009, 9(2): 93-105. 被引量:1
  • 6Croccolo D, de Agostinis M, Vincenzi N. A contribution to the selection and calculation of screws in high duty bolted joints[J]. International Journal of Pressure Vessels and Piping, 2012, 96: 38-48. 被引量:1
  • 7Croccolo D, de Agostinis M, Vincenzi N. Failure analysis of bolted joints: Effect of friction coefficients in torque-pre loading relationship[J]. Engineering Failure Analysis, 2011, 18(1): 364-373. 被引量:1
  • 8Dinger G, Friedrich C. Avoiding self-loosening failure of bolted joints with numerical assessment of local contact state[J]. Engineering Failure Analysis, 2011, 18(8): 2188-2200. 被引量:1
  • 9Chaib Z, Daidie A, Leray D. Screw behavior in large diameter slewing bearing assemblies: numerical and experimental analyses [J]. International Journal on Interactive Design and Manufacturing, 2007, 1(1): 21-31. 被引量:1
  • 10赵海川,黄海江.风电行业高强螺栓的润滑问题分析[J].风能,2010(6):64-66. 被引量:9