期刊文献+

地源热泵地埋管换热性能的边界元法分析 被引量:2

BOUNDARY ELEMENT ANALYSIS OF HEAT TRANSFER OF BURIED PIPES IN GSHP
下载PDF
导出
摘要 建立地埋管传热过程的二维稳态模型,分制冷和供热2种工况,考虑周围土壤温度、回填材料、管径、管材、管内介质的流量和进出口温差等参数的影响。采用适用于薄体的边界元法计算地埋管传热问题,根据计算结果比较不同管壁厚度情况下竖直地埋管的换热差异,为地埋管的设计和运行指标提供定量分析依据。进一步分析不同管材对U型竖直地埋管换热量的影响,并计算两种工况下竖直管道所需的埋设长度。边界元法分析U型等地埋管传热问题,使用较少的单元数可获得较精确的结果,尤其是对该文中管壁薄体和土壤厚体的耦合问题。 A two-dimension steady-state heat transfer model about the buried pipe was established based on the reasonable simplification. The influence of the main parameters of the buried pipe system , such as soil temperature, flux and temperature difference of the medium between inlet and outlet of the pipe, as well as diameter dimension, wall thickness and material of the pipe on the heat transfer efficiency was considered. The heat transfer between the buried pipes and ground source subjected to two cases of cooling and heating was analyzed by a special boundary element method (BEM) which was able to deal with the thin body. Then the heat transfer performance of the vertical buried pipe with respect to its heat transfer coefficient, diameter dimension and wall thickness were discussed according to the computed results. Furthermore, the heat transfer capacity of the single U-type vertical buried pipe was evaluated by the BEM so that the vertical lengths of the buried pipe related to the two cases were obtained. The BEM uses very less number of elements and achieves more accurate results in evaluating the heat transfer of the buried pipes in comparison with the FEM. Especially, the BEM is able to solve the coupling problems of both thin and thick bodies.
出处 《太阳能学报》 EI CAS CSCD 北大核心 2015年第4期936-942,共7页 Acta Energiae Solaris Sinica
基金 国家自然科学基金(11272111 11102056)
关键词 地源热泵 地埋管 传热 边界元法 薄体 ground source heat pump buried pipe heat transfer boundary element method thin body
  • 相关文献

参考文献8

二级参考文献30

  • 1高祖锟.用于供暖的土壤-水热泵系统[J].暖通空调,1995,25(4):9-12. 被引量:21
  • 2杨卫波,施明恒.地源热泵中U型埋管传热过程的数值模拟[J].东南大学学报(自然科学版),2007,37(1):78-83. 被引量:27
  • 3Deerman J D, Kavanaugh S R. Simulation of vertical U-tube groun&coupled heat pump systems using the cylindrical heat source solution [G]//ASHRAE Trans, 1991,97 (1) : 287- 294. 被引量:1
  • 4Yavuzturk C, Spitler J D, Ree S J. A transient two-dimensional finite volume model for the simulation of vertical U-tube ground heat exchangers[ G]// ASHRAE Trans, 1999,105(2) :465- 474. 被引量:1
  • 5Bi Yuehong, Chen Lingen, Wu Chih. Ground heat exchanger temperature distribution analysis and experimental verification [J]. Applied Thermal Engineering, 2002,22(2) : 183-189. 被引量:1
  • 6Katsunori Nagano, Takao Katsura, Sayaka Takeda. Development of a design and performance prediction tool for the ground source heat pump system[J]. Applied Thermal Engineering, 2006, 26 ( 14/15):1578-1592. 被引量:1
  • 7Lei T K. Development of a computational model for a ground-coupled heat exchanger [ G ]//ASHRAE Trans, 1993,99(1) : 149-159. 被引量:1
  • 8Rottmayer S P, Beckman W A, Mitchell J W. Simulation of a single vertical U-tube ground heat exchanger in an infinite medium [G]//ASHRAE Trans, 1997,103(2) : 651- 659. 被引量:1
  • 9Lee C K, Lam H N. Computer simulation of borehole ground heat exchangers for geothermal heat pump systems[J].Renewable Energy, 2008,33(6): 1286-1296. 被引量:1
  • 10Gopal Bandyopadhyay, William Gosnold, Michael Mann. Analytical and semi-analytical solutions for short-time transient response of ground heat exchangers [J].Energy and Buildings, 2008, 40 (10): 1816-1824. 被引量:1

共引文献103

同被引文献15

引证文献2

二级引证文献3

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部