冷弯薄壁型钢结构墙体-楼盖连接中构件数量大,合理简化各构件间的连接作用是建立正确有限元模型的关键,已有研究表明,轴压比对梁柱连接体系抗震性能影响较大。本文结合冷弯壁型钢结构墙体-楼盖连接节点试验,采用有限元计算方法对试验试件进行计算,并进行了改变轴压比参数的分析。结果表明:1螺钉耦合加界面接触建模方法计算结果与试验结果吻合,该模型能用于冷弯薄壁型钢结构墙体-楼盖连接节点力学性能分析;2墙体轴压比对连接节点的力学性能影响很大,轴压比越大,节点承载力越小,耗能能力越低,建议设计轴压比不超过0.6。
The rational finite element analysis model can conduct a detailed parametric analysis, and get the influence to the model induced by parameter variation. Cold-formed thin-walled steel wall-floor connection component ranges, and the connection is complex, rational connection between the various components is the key to establish a correct finite element model. In this paper, based on the cold-formed thin-walled steel wall-floor joint test, explore a reasonable simplified finite element method and conducts a parametric analysis. The results showed that: ① Screw coupling plus interfacial contact modeling results coincides with the experimental results, the model can be used for cold-formed thin-walled steel wall-floor joint mechanical analysis. ② Wall axial compression ratio has great influence on the mechanical properties of the joint:the greater of axial compression ratio,the smaller of joint capacity and the lower of energy dissipation capacity. Proposed design of axial compression ratio is no more than 0. 6.