摘要
针对田集发电厂二期3号锅炉再热蒸汽623℃锅炉高温再热器出口集箱T92管座的高温运行可靠性进行分析。从材料抗氧化性能和持久强度两方面进行了入手。可靠性分析表明,高温再热器出口集箱T92管座能够安全可靠运行,同时提出了相关跟踪保证措施。
The operation reliability analysis results of the reheater terminal header's T92 tube support are reported in this paper in detail. The boiler is the No. 3 set, at the second stage of TianJi project, and the reheat steam temperature is 623℃. Both the oxidation resistance and endurance strength have been analyzed and it is believed that T92 tube support can work safely and reliably under reasonable controlling. Also, related measurements are proposed for tracking and guaranteeing.
出处
《锅炉技术》
北大核心
2015年第A01期1-3,25,共4页
Boiler Technology
基金
科技部国家高科技研究发展计划(863计划)(2012AA050502)