期刊文献+

320排螺旋CT冠状动脉造影对冠心病的筛选诊断 被引量:1

320 row spiral CT coronary angiography in screening for coronary heart disease
下载PDF
导出
摘要 目的:探讨320排螺旋CT冠状动脉成像与冠状动脉血管造影对冠心病的诊断价值。方法:对100例冠心病患者进行CT冠状动脉造影检查后,其中25例患者亦进行了介入冠状动脉造影检查,比较2组检查结果间的差异。结果:以冠状动脉造影结果为金标准,320排螺旋CT冠状动脉成像诊断冠状动脉狭窄敏感度高,与冠状动脉造影检查的结果基本一致。CT冠状动脉造影能清晰地显示冠状动脉的左右主支及分支的全貌图像,能直观地观察到冠状动脉血管壁有无狭窄、钙化等情况。结论:320排螺旋CT冠状动脉造影对血管的狭窄、钙化病变及支架管腔显示准确率较高,且操作相对简单,时间短、无创、费用低,可作为常规冠心病的筛查体检和冠状动脉支架术后复查的检查方法。 Objective To explore the value of 320 row spiral CT coronary artery imaging and coronary angiography in diagnosis of coronary artery disease. Methods Totally 100 coronary heart disease patients underwent CT coronary angiography, of whom, 25 ones went through interventional coronary angiography also. The results by the two examinations were compared. Results With the results by coronary angiography as the golden standard, 320 row spiral CT coronary artery imaging behaved well in the diagnosis of coronary artery stenosis, and had the same results as those by coronary angiography. Coronary angiography could display the left, right coronary arteries and branches clearly, as well as the stenosis,calcification and etc in coronary artery wall. Conclusion 320 row spiral CT coronary angiography can show clearly the vessel stenosis, calcification and bronchial cavity with easy operation, short time, no invasion and low cost, and thus can be the conventional examination for screening of coronary artery disease and reexamination after coronary stenting.
作者 高玉川
出处 《医疗卫生装备》 CAS 2014年第10期85-87,共3页 Chinese Medical Equipment Journal
关键词 320排螺旋CT 冠状动脉造影 血管狭窄 冠心病 320 row spiral CT coronary angiography vascular stenosis coronary artery disease
  • 相关文献

参考文献6

二级参考文献27

  • 1赵为涛,杨勇.冠心病合并糖尿病患者的冠脉造影分析[J].中国现代药物应用,2009,3(6):89-90. 被引量:7
  • 2蒋学祥,邱建星,王继琛,孙晓伟,高莉,高福生,王仪生.64层螺旋CT冠状动脉成像质量的研究[J].中国医学影像技术,2006,22(10):1452-1455. 被引量:31
  • 3[1]Davidson C, Fishman R, Bonow R. Heart disease: A textbook of cardiovascular medicine. Philadelphia, Pa: WB Saunders, 1997, 117 被引量:1
  • 4[2]Agatston AS, Janowits WR, Hildner FJ,et al. Quantification of coronary artery calcium using ultrafast computed tomography. J Am Coll Cardil, 1990, 15:827 被引量:1
  • 5[4]Budoff M, Oudiz RJ, Zalzce C,et al. Intravenous three-dimensional coronary angiography using contrast-enhanced electron beam computed tomography. Am J Cardiol, 1999, 83 被引量:1
  • 6[5]Ohnesorge B, Flohr M, Becher C,et al. Cardiac imaing by means of electrocardiographically gated multisection spiral CT: Initial experience. Radiology, 2000, 217:564 被引量:1
  • 7[6]Becher C, Knez A, Ohnesorge B,et al. Imaging of noncalcified coronary plaques using helical CT with retrospective ECG gating. AJR, 2000, 175:423 被引量:1
  • 8[7]Nieman K, Oudkerk M, Rensing B,et al. Cronary angiography with multi-slice computed tomography. Lancet, 2001, 357:599 被引量:1
  • 9[8]Achenbach S, Ulzheimer S, Baum U,et al. Noinvasive coronary angiography by retrospectively ECG-gated multislice spiral CT. Circulation, 2000, 102:2823 被引量:1
  • 10[9]Achenbach S, Giesler T, Ropers D,et al. Detectiong of coronary artery stenoses by contrast-enhanced, retrospectively electrocardiographically-gated multislice spiral computed tomography. Circulation, 2001, 103:2535 被引量:1