A New Full Bridge High Intensity Focused Ultrasound Power System with Harmonic Cancellation

A New Full Bridge High Intensity Focused Ultrasound Power System with Harmonic Cancellation
原文传递
导出
摘要 The feasibility of a new full bridge high intensity focused ultrasound(HIFU) amplifier system with harmonic cancellation is evaluated in this study. Harmonic cancellation technique is applied to these power amplifiers, which can eliminate the 3rd harmonic and all even harmonics. Since this technique requires two channels of phase signal to control one channel of power amplifier, the signal generator is required to double its output. The transducer array proposed in this study has 100 elements. So we choose an FPGA chip to generate 200 driving signals, and each channel has a phase resolution of 2ns, less than 1°. The phase signal from the FPGA meets the requirement of driving the power amplifiers. The output waveform of one channel of power amplifier(voltage across the transducer) is evaluated, and shows fewer harmonic components. The feasibility of a new full bridge high intensity focused ultrasound(HIFU) amplifier system with harmonic cancellation is evaluated in this study. Harmonic cancellation technique is applied to these power amplifiers, which can eliminate the 3rd harmonic and all even harmonics. Since this technique requires two channels of phase signal to control one channel of power amplifier, the signal generator is required to double its output. The transducer array proposed in this study has 100 elements. So we choose an FPGA chip to generate 200 driving signals, and each channel has a phase resolution of 2 ns, less than 1°. The phase signal from the FPGA meets the requirement of driving the power amplifiers. The output waveform of one channel of power amplifier(voltage across the transducer) is evaluated, and shows fewer harmonic components.
出处 《Journal of Shanghai Jiaotong university(Science)》 EI 2014年第6期698-701,共4页 上海交通大学学报(英文版)
基金 the National Natural Science Foundation of China(No.30800246) the Shanghai Key Technologies R&D Program of China(No.09441900500) the Research Program of Shanghai Education Commission(No.14CXY05)
关键词 high intensity focused ultrasound(HIFU) power amplifier field programmable gate array(FPGA) signal generator harmonic cancellation high intensity focused ultrasound(HIFU) power amplifier field programmable gate array(FPGA) signal generator harmonic cancellation
  • 相关文献

参考文献8

  • 1SUZUKI T, MIZUTANI Y, IKEDA H, et al. Impedance characteristic of ultrasonic transducer operated as load of MOSFET DC-to-RF power inverter[c]1122nd International Conference on Industrial Electronics, Control, and Instrumentation. Taipei, China: IEEE, 1996: 987-990. 被引量:1
  • 2MIZUTANI Y, SUZUKI T, ISHIKAWA J, et al. Singleended compact MOSFET power inverter with automatic frequency control for maximizing RF output power in megasonic transducer at 3 MHz[c]1 11998 IEEE International Symposium on Circuits and Systems. Monterey, USA: IEEE, 1998: 578-581. 被引量:1
  • 3SUZUKI T, IKEDA H, YOSHIDA H, et al. Megasonic transducer drive utilizing MOSFET DC-to-RF inverter with output power of 600 W at 1 MHz[J]. IEEE Transactions on Industrial Electronics, 1999, 46(6): 1159- 1173. 被引量:1
  • 4HALL T, CAIN C. A low cost compact 512 channel therapeutic ultrasound system for transcutaneous ultrasound surgery[CJI 15th International Symposium on Therapeutic Ultrasound. Boston, USA: AlP Publishing, 2006: 445-449. 被引量:1
  • 5TANG S C, CLEMENT G T. A harmonic cancellation technique for an ultrasound transducer excited by a switched-mode power converter[J]. IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control, 2008, 55(2): 359-367. 被引量:1
  • 6MIZUTANI Y, SUZUKI T, IKEDA H, et al. Frequency control of MOSFET full bridge power inverter for maximizing output power to megasonic transducer at 3 MHz[c]1 I Industry Applications Conference. Saint Louis, USA: IEEE, 1998: 1644-1651. 被引量:1
  • 7IKEDA H, SUZUKI T, HAYEIWA K, et al. Output power and efficiency tradeoff in full-bridged MOSFET power inverter for use at shortwave frequencies[c]1 I Industry Applications Society Annual Meeting. Dearborn, USA: IEEE, 1991: 965-970. 被引量:1
  • 8SUZUKI T, IKEDA H, MIZUTANI Y, et al. Full-bridged MOSFET DC-to-RF inverter for high frequency ultrasonic transducer at 3 MHz[C]/ / IEEE International Symposium on Industrial Electronics. Athens, Greece: IEEE, 1995: 232-236. 被引量:1