期刊文献+

Quantitative Analysis of Fe Content in Iron Ore via External Calibration in Conjunction with Internal Standardization Method Coupled with LIBS 被引量:2

Quantitative Analysis of Fe Content in Iron Ore via External Calibration in Conjunction with Internal Standardization Method Coupled with LIBS
原文传递
导出
摘要 The external calibration in conjunction with internal standardization(ECIS) coupled with laser-induced breakdown spectroscopic(LIBS) technique was proposed to perform the quantitative analysis of Fe content in iron ore The plasma temperature and the electron number density were calculated to prove that the plasma was under local thermodynamic equilibrium(LTE) conditions and to ensure that the integral intensities of Fe I lines were reasonable. In addition, the result of the quantitative analysis shows a content of (20.26±0.59)% by mass of Fe in the iron ore. It was determined by four calibration curves, drawn for four emission lines of Fe I(373.48, 373.71,404.58 and 438.35 nm) normalized by Mn I line, base on the ECIS method which can eliminate the influence of matrix effect and improve the accuracy of quantitative analysis, compared with the standard addition method. Both the results of these two analytical methods were compared with that listed in the Standard Substance Certificate. The percentage content of Fe in the same sample of iron ore by the ECIS method was (20.17±0.08)% by mass, which shows a good performance to analyze the Fe content of iron ore in combination with LIBS. The external calibration in conjunction with internal standardization(ECIS) coupled with laser-induced breakdown spectroscopic(LIBS) technique was proposed to perform the quantitative analysis of Fe content in iron ore The plasma temperature and the electron number density were calculated to prove that the plasma was under local thermodynamic equilibrium(LTE) conditions and to ensure that the integral intensities of Fe I lines were reasonable. In addition, the result of the quantitative analysis shows a content of (20.26±0.59)% by mass of Fe in the iron ore. It was determined by four calibration curves, drawn for four emission lines of Fe I(373.48, 373.71,404.58 and 438.35 nm) normalized by Mn I line, base on the ECIS method which can eliminate the influence of matrix effect and improve the accuracy of quantitative analysis, compared with the standard addition method. Both the results of these two analytical methods were compared with that listed in the Standard Substance Certificate. The percentage content of Fe in the same sample of iron ore by the ECIS method was (20.17±0.08)% by mass, which shows a good performance to analyze the Fe content of iron ore in combination with LIBS.
出处 《Chemical Research in Chinese Universities》 SCIE CAS CSCD 2015年第1期107-111,共5页 高等学校化学研究(英文版)
基金 Supported by the China Instrumentation Program(No.2011YQ030113) and the National Natural Science Foundation of China (Nos.21175106, 21375105).
关键词 Laser-induced breakdown spectroscopy(LIBS) External calibration in conjunction with internal standardization(ECIS) method Chemical analysis Iron ore Laser-induced breakdown spectroscopy(LIBS) External calibration in conjunction with internal standardization(ECIS) method Chemical analysis Iron ore
  • 相关文献

参考文献28

  • 1Iron Ores--Determination of Calcium, Silicon, Manganese, Tita- nium, Phosphorus, Magnesium, Aluminium and Barium Content- Wavelength Dispersive X-ray Fluorescence Spectrometric Method, GB/T 6730.62-2005. 被引量:1
  • 2Death D. L. , Cunningham A. P Part B, 2008, 63, 763. 被引量:1
  • 3LiuJ. , Li Z. L., Vogel W., Yang H., Chem. Res. Chinese Universities, 2012, 28(3), 511. 被引量:1
  • 4Brai M., Germaro G., Schillaci T., Tranchina L., Spectrochint Acta Part B, 2009, 64, 111. 被引量:1
  • 5Gurell J., Bengtson A., Falkenstrom M., Hansson B. A. M., Spectrochim. Acta Part B, 2012, 67, 446. 被引量:1
  • 6Cabalin L. M., Gonzalez A., Ruiz J., Laserna J. J., Spectrochim. Acta Part B, 2010, 65, 680. 被引量:1
  • 7Nunes L. C., Silva G. A., Trevizan L. C., Santos Junior D., Poppi R. J., Krug E J., Spectrochim. Acta Part B, 2009, 64, 565. 被引量:1
  • 8Lin Q., Wei Z., Xu M., Wang S., Niu G., Liu K., Duan Y, Yang J., RSC Adv., 2014, 4, 14392. 被引量:1
  • 9Gottfried J. L., Analytical and Bioanalytical Chemistry, 2011, 400, 3289. 被引量:1
  • 10Singh J. t, Thakur S. N., Laser-induced Breakdown Spectroscopy, Elsevier, Amsterdam, 2007. 被引量:1

同被引文献26

引证文献2

二级引证文献12

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;