摘要 构建肺部呼吸运动模型时,为了快速准确地确定序列影像在呼吸周期中的位置,提出了一种距离对应关联法,通过标记物相同时间段内在4D CT中和呼吸信号中的位移量的比较,确定4D CT和呼吸信号的对应关系.采用该方法建立双目立体视觉系统获取的呼吸信号和4D CT的对应关系,并以构建的肺部呼吸运动线性模型的模型误差验证方法的有效性.试验结果表明,基于距离对应关联法构建的肺部线性模型的模型误差在2.5 mm以内,相对于梯度对应关联法,模型误差降低超过10%;本方法简单易行、精度高,适合构建序列影像与呼吸信号间的对应关系. To quickly and accurately assign the positions of sequential images in respiratory cycle for building lung respiratory motion model,a novel distance correlation method was proposed to determine the corresponding relationship between 4D CT and respiratory signal by comparing the distance of in vitro labeling in 4D CT datasets with respiratory signal over the same time period. The proposed method was used to construct the correlational relationships between respiratory signal obtained by binocular visual system and 4D CT. The model error of a linear lung motion model built by the proposed method was calculated to evaluate the effectiveness of the proposed method. The error of the linear lung motion model based on the distance correlation method was within 2. 5 mm. Compared with the motion model based on the gradient correlation method,the error was reduced more than 10%. Experimental results show that the proposed method is feasible and effective with high accuracy,and it is suitable for constructing the relationship between sequential images and respiratory signal.
出处 《江苏大学学报(自然科学版)》 EI CAS CSCD 北大核心 2015年第2期187-190,共4页 Journal of Jiangsu University:Natural Science Edition
基金 国家自然科学基金资助项目(81371640) 江苏省科技计划项目(BL2012049) 苏州市科技计划项目(SH201210)
关键词 运动模型 序列影像 标记物 呼吸信号 对应关系 motion model sequential images in vitro labeling respiratory signal corresponding relationship
  • 相关文献

参考文献12

  • 1Ehrhardt J,Lorenz C. 4D Modeling and Estimation ofRespiratory Motion for Radiation Therapy [ M]. Tennes-see :Springer, 2012. 被引量:1
  • 2McClelland J R,Hawkes D J, Schaeffter T,et al. Re-spiratory motion models: a review [ J]. Medical ImageAnalysis, 2013,17(1) : 19 -42. 被引量:1
  • 3Fay ad H, Pan T,Clement J F, et al. Technical note:correlation of respiratory motion between external patientsurface and internal anatomical landmarks [ J ] ? MedicalPhysics, 2011,38(6) : 3157 -3164. 被引量:1
  • 4Ernst F, Bruder R, Schlaefer A, et al. Correlation be-tween external and internal respiratory motion : a valida-tion study [ J ]. Int J Comput Assist Radiol Surg,2011,6 (5) : 483 -492. 被引量:1
  • 5Fay ad H,Pan T,Pradier 0,et al. Patient specific re-spiratory motion modeling using a 3D patient7s externalsurface [ J ]. Medical Physics,2012,39 ( 6 ) : 3386 -3395. 被引量:1
  • 6文丽丽,罗洪艳,张绍祥,郑小林,吴毅,李敏.基于运动跟踪获取人体呼吸曲线的初步研究[J].中国生物医学工程学报,2012,31(4):512-517. 被引量:6
  • 7McClelland J R, Blackall J M,Tarte S,et al. A conti-nuous 4D motion model from multiple respiratory cyclesfor use in lung radiotherapy [ J ]. Medical Physics,2006,33(9) : 3348 -3358. 被引量:1
  • 8夏威,高欣,王雷,周志勇,张冉.基于点集与互信息的肺部CT图像三维弹性配准算法[J].江苏大学学报(自然科学版),2014,35(5):558-563. 被引量:3
  • 9Li R, Lewis J, Jia X, et al. On a PCA-based lung mo-tion model [ J ]. Physics in Medical and Biology,2011,56(18) : 6009 -6030. 被引量:1
  • 10Chang K H,Ho M C, Yeh C C, et al. Effectiveness ofexternal respiratory surrogates for in vivo liver motion es-timation [ J ]. Medical Physics, 2012, 39(8): 5293 -5301. 被引量:1

二级参考文献31

  • 1王冰,职秦川,张仲选,耿国华,周明全.灰度图像质心快速算法[J].计算机辅助设计与图形学学报,2004,16(10):1360-1365. 被引量:32
  • 2宁徐彷,姚毅,全红,陈文艳,胡广,徐琳.双摄像机获取人体呼吸信号的探讨[J].武汉大学学报(医学版),2007,28(3):319-321. 被引量:1
  • 3Lu Wei, Parikh PJ, Hubenschmidt JP, et al. A comparison between amplitude sorting and phase-angle sorting using external respiratory measurement for 4D CT [ J ]. Medical Physics, 2006, 33 (8) : 2964 - 2974. 被引量:1
  • 4Wink NM, Panknin C, Solberg TD, et al. Phase versus amplitude sorting of 4D-CT data [ J ]. Journal of Applied Clinical Medical Physics, 2006, 7 ( 1 ) : 77 - 85. 被引量:1
  • 5Low DA, Nystrom M, Kalinin E, et al. A method for the reconstruction of four - dimensional synchronized CT scans acquired during free breathing [ J ]. Medical Physics, 2003, 30 (6) : 1254 - 1263. 被引量:1
  • 6Vedam SS, Keall PJ, Kini VR, et aL Acquiring a four- dimensional computed tomography dataset using an external respiratory signal [ J]. Physical in Medicine and Biology, 2003, 48(1) : 45 -62. 被引量:1
  • 7Keall PJ, Starkschall G, Shukla H, et al. Acquiring 4D thoracic CT scans using a multislice helical method [ J ]. Physical in Medicine and Biology, 2004, 49 (10) :2053 -2067. 被引量:1
  • 8Keall PJ, Kini VR, Vedam SS, et al. Potential radiotherapy improvements with respiratory gating [ J]. Australas Phys Eng Sci Med, 2002, 25(1): 1 -6. 被引量:1
  • 9Mageras GS, Yorke E, Rosenzweig K, et al. Fluoroscopic evaluation of diaphragmatic motion reduction with a respiratory gated radiotherapy system [ J ]. Applied Clinical Medical Physics, 2001, 2(4) : 191 -200. 被引量:1
  • 10Lujan AE, Larsen EW, Baher JM, et al. A method for incorporating organ due to breathing into 3D dose calculations [J]. Medical Physics, 1999, 26(5), 715 -720. 被引量:1

共引文献7

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部